Clinical Research Directory
Browse clinical research sites, groups, and studies.
Safety and Efficacy of DCB Therapy for ISR Under the Guidance of QFR (UNIQUE-DCB-II Study )
Sponsor: Nanjing First Hospital, Nanjing Medical University
Summary
In 1970, the first percutaneous balloon coronary angioplasty opened a new chapter of interventional therapy. However, the incidence of intracoronary restenosis was about 30%. Subsequently, bare metal stents and drug-eluting stents (DES) reduced the incidence of in-stent restenosis (ISR) to 5%-10% and it was still a bottleneck treated by percutaneous coronary intervention (PCI). Currently, ISR is mainly treated by balloon angioplasty, stent implantation and coronary artery bypass grafting. In 2014, the guidelines of the European Society of Cardiology recommended that drug balloon therapy (DCB) and new generation DES should be the preferred strategies for ISR treatment. Compared with DES, DCB treatment can avoid the inflammation of intima caused by multi-layer stent strut, and reduce the risk of intimal hyperplasia and thrombosis in stent. However, DCB lacks sustained radial support. Even if the residual stenosis is less than 30% after sufficient pre-dilation, the elastic retraction of the intima still exists. In addition, the antiproliferative effect of paclitaxel is significantly worse than that of sirolimus and its derivatives, and there is a lack of long-term sustained release of anti-proliferative drugs. Compared with DCB, DES can obtain long-term stable radial support and long-term anti-proliferation effect, but stent struts exposed in the vascular lumen are at risk of stent thrombosis. The new generation of DES improves the design of stent platform, improves the polymer coating, and applies new anti-proliferative drugs. It effectively reduces the inflammation of vascular wall, speeds up the process of vascular re-endothelialization, promotes early vascular repair, and significantly reduces the incidence of stent thrombosis. Recent BIOLUXRCT, RESTORE and DARE studies provide more powerful evidence for the treatment of ISR by new generation DES. Quantitative flow ratio (QFR) is the second generation FFR detectional method based on coronary contrast image. The latest FAVOR II results also confirm that QFR is more sensitive and specific than quantitative coronary analysis (QCA) in the diagnosis of myocardial ischemia caused by coronary artery stenosis. However, there is no report of ISR treated with DCB under the guidance of QFR. The aim of this study was to evaluate the safety and efficacy of DCB in the treatment of in-stent restenosis in patients with coronary heart disease (CHD) under the guidance of QFR compared with DES implantation.
Official title: Safety and Efficacy of Drug Coated Balloon Therapy for Coronary In-stent Restenosis in Patients With Coronary Heart Disease Under the Guidance of QFR (UNIQUE-DCB-II Study)
Key Details
Gender
All
Age Range
18 Years - 100 Years
Study Type
INTERVENTIONAL
Enrollment
220
Start Date
2026-01-01
Completion Date
2028-12-01
Last Updated
2025-05-31
Healthy Volunteers
No
Conditions
Interventions
drug coated balloon
Balloon/vessel diameter ratio 0.8-1.0, 8-12 ATM (atmosphere), lasting for \>30 seconds.
drug eluted stent
with regular techniques
Locations (1)
Nanjing First Hospital
Nanjing, Jiangsu, China