Tundra Space

Tundra Space

Clinical Research Directory

Browse clinical research sites, groups, and studies.

Back to Studies
RECRUITING
NCT04129021
NA

High Resolution, High-speed Multimodal Ophthalmic Imaging

Sponsor: Centre Hospitalier National d'Ophtalmologie des Quinze-Vingts

View on ClinicalTrials.gov

Summary

Knowledge of the pathogenesis of ocular conditions, a leading cause of blindness, has benefited greatly from recent advances in ophthalmic imaging. However, current clinical imaging systems are limited in resolution, speed, or access to certain structures of the eye. The use of a high-resolution imaging system improves the resolution of ophthalmoscopes by several orders of magnitude, allowing the visualization of many microstructures of the eye: photoreceptors, vessels, nerve bundles in the retina, cells and nerves in the cornea. The use of a high-speed acquisition imaging system makes it possible to detect functional measurements such as the speed of blood flow. The combination of data from multiple imaging systems to obtain multimodal information is of great importance for improving the understanding of structural changes in the eye during a disease. The purpose of this project is to observe structures that are not detectable with routinely used systems.

Official title: High Resolution and High Speed Multimodal Ophthalmic Imaging

Key Details

Gender

All

Age Range

18 Years - Any

Study Type

INTERVENTIONAL

Enrollment

1200

Start Date

2019-07-03

Completion Date

2027-07

Last Updated

2025-11-18

Healthy Volunteers

Yes

Interventions

DEVICE

High-resolution retinal imaging through adaptive optics

The protocol consists of performing retinal imaging using full-field optical coherence tomography. The participant is asked to put his forehead against the temple supports and his chin on a chin rest. The subject will be asked to fix a test pattern in the form of a cross. The pattern is positioned according to the desired eccentricity with respect to the fovea. The actual acquisition lasts a few seconds, possibly repeated to cover the field of the desired eye. The acquisition protocol depends on the subjects, their pathology and the system used; the area examined will be modified on a case by case basis. The total duration of each exam can be estimated at less than half an hour, with frequent breaks.

DEVICE

High-resolution retinal imaging through holographic systems

The protocol consists of performing retinal imaging using a laser Doppler holography. For each system, the participant is asked to put his forehead against the temple supports and his chin on a chin rest. The subject will be asked to fix a test pattern in the form of a cross. The pattern is positioned according to the desired eccentricity with respect to the fovea. The actual acquisition lasts a few seconds, possibly repeated to cover the field of the desired eye. The acquisition protocol depends on the subjects, their pathology and the system used; the area examined will be modified on a case by case basis. The total duration of each exam can be estimated at less than half an hour, with frequent breaks.

Locations (1)

Centre Hospitalier National d'Ophtalmologie des Quinze-Vingts

Paris, France