Minimizing Facial Nerve Stimulation in Cochlear Implants
Sponsor: Cambridge University Hospitals NHS Foundation Trust
Summary
This study aims to understand how to manipulate the electrical stimulation from the cochlear implant to maximize hearing stimulation and minimize facial stimulation. It is know from animal data that the hearing and facial nerves have different sensitivities to things like electrical pulse shape, its pattern, and its duration. It is very unclear however if this applies to human cochlear implant patients, and what the optimal parameters are to selectively stimulate the hearing nerve in humans. The outcomes of this study will be used to more selectively program some patients with severe facial nerve cross stimulation and to inform the development of new types of implant stimulation.
Key Details
Gender
All
Age Range
18 Years - Any
Study Type
INTERVENTIONAL
Enrollment
24
Start Date
2019-12-13
Completion Date
2028-11-01
Last Updated
2026-11-12
Healthy Volunteers
Yes
Conditions
Interventions
Electrical Stimulation
To measure the facial nerve stimulation threshold for one mid-array and one apical electrode of the implant using the pulse-train stimuli
Locations (1)
Addenbrookes Hospital