Comparison of Imaging Quality Between Spectral Photon Counting Computed Tomography (SPCCT) and Dual Energy Computed Tomography (DECT)

Sponsor: Hospices Civils de Lyon

View on ClinicalTrials.gov

Summary

This pilot study wants to determine to which extent SPCCT allows obtaining images with improved quality and diagnostic confidence when compared to standard Dual Energy CT (DECT), both with and without contrast agent injection. Depending on the anatomical structures/organs to be visualized during CT examinations, different scanning protocols are performed with quite variable ionizing radiation doses. Therefore, in order to obtain the most extensive and representative results of the improvement in image quality between SPCCT and DECT that will be performed CT imaging on several body regions and structures, including diabetic foot, diabetic calcium coronary scoring, adrenal glands, coronary arteries, lung parenchyma, kidney stones, inner ear, brain and joints, earl/temporal bone, colorectal carcinosis.

Key Details

Gender

All

Age Range

18 Years - Any

Study Type

INTERVENTIONAL

Enrollment

339

Start Date

2021-01-29

Completion Date

2026-01-29

Last Updated

2024-04-04

Healthy Volunteers

No

Interventions

DEVICE

Spectral Photon Counting Computed Tomography (SPCCT)

For the dual-layer spectral CT scanner (IQon®, Philips, Amsterdam, The Netherlands), the following parameters will be used for the acquisition: * Tube potential 120 kVp; * Tube current time product of 150 mAs; * Gantry revolution time 0.33 s; * Automatic exposure control (angular and longitudinal) combined xyz-axis; * Beam collimation geometry 64 x 0.625 mm - scan field-of-view - 22 cm;

DEVICE

DECT (Dual Energy CT)

The SPCCT scanner is a prototype spectral photon-counting computed tomography system derived from a modified clinical CT system with a field-of-view (FOV) of 168 mm in-plane, and a z-coverage of 20 mm. It is equipped with energy-sensitive photon-counting detectors relying on the direct conversion high band gap semiconductor of cadmium zinc telluride (CZT). The electronics comprises 5 rate counters with 5 different configurable energy thresholds. The SPCCT scanner has the following parameters: * Base platform : iCT scanner * Tube Voltage (kVp) : 120, capability for imaging at 80 and 100 kVp * Tube current (mA) : 10 - 300 * Spatial Resolution : \> 30 lp/cm, ≤ 250 µm * Z-coverage isocenter (mm) : 20 mm * FOV (mm) : 500 * Minimum rotation time : 0.33 s/rotation * Acquisition modes : Axial, Helical, Step \& Shoot