The Basel CardioInsightTM - 3D Mapping Study
Sponsor: University Hospital, Basel, Switzerland
Summary
This study is to describe the exact location of NOAF-maintaining foci and rotors after cardiac surgery identified by mapping using the non-invasive phase mapping with CardioInsightTM - 3D Mapping technology (CardioInsightTM, Medtronic Switzerland, Tolochenaz, Switzerland) and a low-dose computed tomography scan of the chest.
Official title: Non-invasive Evaluation of New-onset Atrial Fibrillation After Cardiac Surgery The Basel CardioInsightTM - 3D Mapping (BigMap) Study
Key Details
Gender
All
Age Range
18 Years - Any
Study Type
OBSERVATIONAL
Enrollment
157
Start Date
2022-04-12
Completion Date
2028-12
Last Updated
2025-04-09
Healthy Volunteers
No
Conditions
Interventions
Mapping
CardioInsightTM Cardiac Mapping System is a non-invasive single beat cardiac mapping system that provides three-dimensional electroanatomic maps of the heart. The CIT vest is attached to the patient's torso for non-invasive mapping. To ensure correct and rapid mapping of the NOAF by the CIT device, it is essential to briefly slow down the patient's heart rate below 50bpm for a few seconds. Therefore 6mg adenosine as a rapid i.v. bolus will be administered. The adenosine application will slow down the patient's heart rate and allow for correct mapping by the CIT device. Medical therapy of atrial fibrillation is started immediately according to local protocol. Since non-invasive mapping is performed within a few minutes, the therapy of atrial fibrillation will not be critically delayed. Consecutively, a low-dose thoracic computed tomography (CT) scan (neck to upper abdomen) will be performed independent from the patient's rhythm.
Computed tomography scan
The CT scans will follow a standardised protocol as predefined by the manufacturer of the CIT vest, Medtronic (Dublin, Ireland). After the sensor array has been placed on the patient, the patient is ready to undergo a CT scan to register each electrode's locations with respect to the body surface. All CT scans cover a body region from neck to the upper abdomen, have no cardiac gating performed or any contrast agent given. The CT scans are acquired on 3 CT scanners manufactured by Siemens Corporation (Berlin, Germany) with a fixed tube voltage of 80 kVp and 250 effective mAs (=mAs/pitch). The reconstruction parameters are of 3 mm slice thickness and of 1.5 mm increment (slice overlap) The estimated effective dose (ED) is 3.2 mSv per patient.