Clinical Research Directory
Browse clinical research sites, groups, and studies.
Transcatheter Aortic Valve Implantation Versus Standard Surgical Aortic Valve Replacement
Sponsor: Centre Cardiologique du Nord
Summary
The mechanical intervention is treating aortic valve stenosis (AVS) which may be performed using the standard open surgical approach for aortic valve replacement (AVR) or transcatheter aortic valve implantation (TAVI). The key question of this study is to establish the difference in all-cause and cause-specific (cardiac vs noncardiac) mortality, all hospitalizations for heart failure within 24 months of follow-up, left ventricular reverse remodeling after adjustment for death, as assessed by means of the left ventricular end-diastolic volume (LVEDV), in patients who received the TAVI vs the standard surgical procedure for AVS.
Official title: Transcatheter Aortic Valve Implantation Versus Standard Surgical Aortic Valve Operation for Aortic-Valve Stenosis in Patients at Risk to Severe Valve Obstruction.
Key Details
Gender
All
Age Range
18 Years - 90 Years
Study Type
OBSERVATIONAL
Enrollment
4000
Start Date
2013-01-01
Completion Date
2025-12-31
Last Updated
2025-03-05
Healthy Volunteers
Not specified
Interventions
Transcatheter Aortic Valve Implantation
Patients who are deemed receive TAVI first underwent evaluation of their peripheral arteries before the procedure, in order to separate those eligible for transfemoral placement (TFP) from those who would require transapical placement. Technological advances achieved in the new platforms for the treatment of SHD have allowed the use of reduced size catheters and sheaths in the new armamentarium, favoring the TFP technique. The transcatheter valve (TV) is positioned at the level of the native aortic valve during the final step of valve replacement, when the balloon is inflated within the native valve during a brief period of rapid ventricular pacing. The delivery system i traverses the aorta retrograde over a guidewire from its point of insertion in the femoral artery during the use of TFP. Before balloon inflation, the valve and balloon are collapsed on the catheter and fit within the sheath. After balloon inflation, the calcified native valve is replaced by the expanded TV
Bioprothesis
The bioprosthesis is implanted using the SAVR procedure during median sternotomy in extracorporeal circulation. Minimally invasive procedures using a thoracotomy approach and peripheral cannulation have found widespread use.
Sutureless
The sutureless is implanted using the SAVR procedure during median sternotomy in extracorporeal circulation. Minimally invasive procedures using a thoracotomy approach and peripheral cannulation have found widespread use.
Locations (1)
Francesco Nappi
Saint-Denis, France