Clinical Research Directory
Browse clinical research sites, groups, and studies.
Physician Modified Endograft For Complex Aortic Aneurysm Repair
Sponsor: University of California, Davis
Summary
The physician modified endograft is intended for treating complex, pararenal, juxtarenal and thoracoabdominal aortic aneurysms requiring coverage of renal arteries, the superior mesenteric artery or the celiac trunk in high-risk patients who do not have an option for endovascular repair with an FDA approved endograft and have an appropriate anatomy. There will be one investigational site with a total of 40 subjects to be enrolled. Time to complete enrollment will be 24 months and the subject follow-up time will be five years from last subject enrollment. The primary safety endpoint is freedom from major adverse events (MAE) at 30 days or during hospitalization if this exceeds 30 days. The primary effectiveness endpoint is the proportion of study subjects with treatment success at one year. The subjects will be followed at one month, six months, one year, and yearly thereafter for a total period of five years. Subjects will be followed up clinically for life. Clinical exam follow up may be phone or video visit with CT scan evaluation and duplex ultrasound as needed. The proportion of treatment group subjects that achieve and maintain treatment success annually to five years will be investigated.
Official title: A Single-Arm, Single-Center, Non-Randomized, Prospective Clinical Study to Evaluate the Safety and Effectiveness of Physician Modified Endograft for Complex Abdominal and Thoracoabdominal Aortic Aneurysm Repair
Key Details
Gender
All
Age Range
18 Years - Any
Study Type
INTERVENTIONAL
Enrollment
40
Start Date
2023-03-01
Completion Date
2029-12
Last Updated
2025-11-10
Healthy Volunteers
No
Conditions
Interventions
Endovascular Treatment of Complex abdominal or Thorocoabdominal aneurysms (TAAA).
Modification * Deploy the graft on the sterile, surgical table * Mark out on the graft the locations of the fenestrations on the graft adjusting as necessary * Using handheld electrocautery, fashion the fenestration in the appropriate location on the moistened graft material in order to prevent inadvertent progression of the fenestration size * If the fenestration is going to remain as such, then a snare is used to fashion the marker on the fenestration with 5-0 stitch * If the fenestration is going to be made into a branch, then an appropriately sized, self-expanding stent is beveled and fashioned to be 15 mm long and sewn to the fenestration in addition to a snare with the 5-0 stitch * Two orientation markers are placed at the proximal edge and distal edge of the graft consisting of portions of the snare sewn to the anterior portion of the graft in a J fashion with a 5-0 stitch
Locations (1)
University of California San Diego
San Diego, California, United States