Clinical Research Directory
Browse clinical research sites, groups, and studies.
The Value of IVL Compared To OPN Non-Compliant Balloons for Treatment of RefractorY Coronary Lesions (VICTORY) Trial
Sponsor: Luzerner Kantonsspital
Summary
Percutaneous coronary intervention (PCI) with drug-eluting stent (DES) implantation has become the dominant treatment strategy for patients with acute and chronic coronary artery disease (CAD) requiring revascularization. Nonetheless, PCI with stent implantation has some limitations and especially patients with severely calcified coronary lesions (approximately 10-20% of all patients with CAD) have an elevated risk for adverse outcomes, including target lesion failure (TLF) and stent thrombosis (ST). Several dedicated PCI devices have been developed for treatment of severely calcified lesions. Whereas especially two of them have shown promising results in smaller, prospective studies. First, the super high-pressure NC PCI balloon (OPN™ NC, SIS Medical AG, Frauenfeld, Switzerland) has been shown to represent an effective and safe device for lesion preparation. Second, the lately introduced Shockwave intravascular lithotripsy (IVL)™ balloon catheter (Shockwave Medical, Santa Clara, CA, USA) appears to be a safe and efficient alternative device for treatment of calcified coronary lesions. However, it remains unknown, if the OPN™ NC balloon is non-inferior to to IVL regarding lesion preparation and completeness of stent expansion in severely calcified lesions.
Official title: The Value of IVL Compared To OPN Non-Compliant Balloons for Treatment of RefractorY Coronary Lesions (VICTORY) Trial - A Randomized, Multicenter, Non-inferiority Comparison of Shockwave Intravascular Lithotripsy (IVL) and the OPN Non-compliant Balloon for Treatment of Calcified and Refractory Coronary Lesions
Key Details
Gender
All
Age Range
18 Years - Any
Study Type
INTERVENTIONAL
Enrollment
280
Start Date
2022-11-22
Completion Date
2028-05-30
Last Updated
2024-06-18
Healthy Volunteers
No
Conditions
Interventions
OPN™ NCB Super High Pressure PCI Balloon
In order to permit advancement of the studied medical devices - OPN™ NCB or Shockwave™ IVL balloon catheter - initial lesion preparation using small SCBs or NCBs (≤2mm) or rotablation (Boston Scientific, Marlborough, MA, United States) is allowed, but will be documented. This may be required in selected cases with very calcified and tight lesions. As per protocol, lesion preparation will be performed using either the super-high pressure PCI balloon OPN™ NCB or the Shockwave™ IVL balloon catheter according to random treatment assignment after matching the angiographic and/or OCT inclusion criteria. Following successful lesion preparation all patients will be treated with a latest generation durable polymer everolimus-eluting stent (Xience™ Sierra or Skypoint, Abbott Vascular Inc., Santa Clara, CA, United States) to allow comparison of stent expansion.
Shockwave™ C2 IVL Catheter
In order to permit advancement of the studied medical devices - OPN™ NCB or Shockwave™ IVL balloon catheter - initial lesion preparation using small SCBs or NCBs (≤2mm) or rotablation (Boston Scientific, Marlborough, MA, United States) is allowed, but will be documented. This may be required in selected cases with very calcified and tight lesions. As per protocol, lesion preparation will be performed using either the super-high pressure PCI balloon OPN™ NCB or the Shockwave™ IVL balloon catheter according to random treatment assignment after matching the angiographic and/or OCT inclusion criteria. Following successful lesion preparation all patients will be treated with a latest generation durable polymer everolimus-eluting stent (Xience™ Sierra or Skypoint, Abbott Vascular Inc., Santa Clara, CA, United States) to allow comparison of stent expansion.
Locations (1)
Luzerner Heart Centre
Lucerne, Switzerland