Tundra Space

Tundra Space

Clinical Research Directory

Browse clinical research sites, groups, and studies.

Back to Studies
ENROLLING BY INVITATION
NCT05376332
NA

Sonomyographic Upper Limb Prosthetics: A New Paradigm

Sponsor: George Mason University

View on ClinicalTrials.gov

Summary

The vast majority of all trauma-related amputations in the United States involve the upper limbs. Approximately half of those individuals who receive a upper extremity myoelectric prosthesis eventually abandon use of the system, primarily because of their limited functionality. Thus, there continues to be a need for a significant improvement in prosthetic control strategies. The objective of this bioengineering research program is to develop and clinically evaluate a prototype prosthetic control system that uses imaging to sense residual muscle activity, rather than electromyography. This novel approach can better distinguish between different functional compartments in the forearm muscles, and provide robust control signals that are proportional to muscle activity. This improved sensing strategy has the potential to significantly improve functionality of upper extremity prostheses, and provide dexterous intuitive control that is a significant improvement over current state of the art noninvasive control methods. This interdisciplinary project brings together investigators at George Mason University, commercial partners at Infinite Biomedical Technologies as well as clinicians at MedStar National Rehabilitation Hospital. The investigators will optimize and implement algorithms for real-time classification and control with multiple degrees of freedom (DOF) using a miniaturized ultrasound system incorporated into a prosthetic socket. The investigators will then compare control performance between and sonomyography and myoelectric control (both direct control and pattern recognition) using a virtual environment as well as for performance of tasks related to activities of daily living. The investigators have two specific aims. Specific Aim 1: Compare between sonomyography and myoelectric direct control Specific Aim 2: Compare between sonomyography and pattern recognition with velocity control The successful completion of this project will lead to the first in human evaluation of an integrated prototype that uses low-power portable imaging sensors and real-time image analysis to sense residual muscle activity for prosthetic control. In the long term, the investigators anticipate that the improvements in functionality and intuitiveness of control will increase acceptance by amputees.

Key Details

Gender

All

Age Range

18 Years - 65 Years

Study Type

INTERVENTIONAL

Enrollment

16

Start Date

2023-11-02

Completion Date

2026-07-31

Last Updated

2026-02-03

Healthy Volunteers

No

Interventions

DEVICE

Sonomyographic Prosthesis

The sonomyographic system will include a custom-fitted test socket incorporating ultrasound transducers and controlling a TASKA prosthetic hand. All socket fittings will be performed by a board-certified prosthetist as part of this study.

DEVICE

Myoelectric direct control prosthesis

The direct control system will include a custom-fitted test socket incorporating dual-site electrodes and controlling a TASKA prosthetic hand. All socket fittings will be performed by a board-certified prosthetist as part of this study.

DEVICE

Myoelectric pattern recognition prosthesis

The pattern recognition system will include the subject's clinically-prescribed socket and commercially-available pattern recognition technology (IBT Sense). The pattern recognition system will not be fitted as part of this study, as subjects will already be trained users prior to enrolling in the study.

Locations (1)

Peterson Health Sciences Hall

Fairfax, Virginia, United States