Tundra Space

Tundra Space

Clinical Research Directory

Browse clinical research sites, groups, and studies.

Back to Studies
NOT YET RECRUITING
NCT05396222
NA

A Prospective Study of the Safety and Efficacy of 3D-printed Non-rigid Biomimetic Implant in Cervical and Thoracolumbar Spine

Sponsor: National Taiwan University Hospital

View on ClinicalTrials.gov

Summary

Vertebral body resection is a wide accepted procedure in tumor resection, deformity correction, and anterior decompression in spondylosis, ossification of posterior longitudinal ligaments, and spondylodiscitis surgery. However, reconstruction of segmental defect is still challenging to spine surgeon, especially in 3-column resection, such as total en bloc spondylectomy in tumor patients. Various graft or prosthesis for reconstruction has been reported, such as structural allograft, Harms mesh cages, expandable cages, and carbon fiber stackable cages. There are no high evidence level study examining the superiority of those different methods. Recently, 3D printed vertebral body replacement has been reported in different disease entities as well, such as tumor, Kümmell's disease in osteoporosis, and spondylosis. 3D printed implant comes with superiority in production of complex geometries and regularity of the fine surface detailed that promote bone ingrowth. Although, 3D-printed titanium vertebra could achieved bone integration in human, a systemic review showed that the subsidence noted in 31.4% of spine surgery with 3D printed implants. In spine surgery, the fixation construct is sufficiently stiff, interbody motion can be reduced, and loading sharing promotes bone fusion. On the other hand, if the reconstruction is too stiff, stress shielding at fusion site occurs. The concept of dynamic fusion, as opposed to rigid fusion, has been demonstrated by an anterior cervical interbody fusion study in porcine model, demonstrating good bone formation, less postfusion stiffness, and a trend to less subsidence. Thus, we developed a 3D printed, custom-made, biomimetic prosthesis, with non-rigid structure, which has been tested in biomechanical study and porcine model, showing good bone formation and less stiffness as well. Therefore, we proposed a prospective clinical study to investigate safety, subsidence, and fusion of this prosthesis.

Official title: A Prospective Study of the Safety and Efficacy of 3D-printed Custom-made Non-rigid Biomimetic Implant for Anterior Column Reconstruction in Cervical and Thoracolumbar Spine

Key Details

Gender

All

Age Range

20 Years - 79 Years

Study Type

INTERVENTIONAL

Enrollment

18

Start Date

2027-01-01

Completion Date

2028-01-01

Last Updated

2025-12-17

Healthy Volunteers

No

Conditions

Interventions

DEVICE

3D-printed custom-made non-rigid biomimetic implant

We developed a 3D printed, custom-made, biomimetic prosthesis, with non-rigid structure, which has been tested in biomechanical study and porcine model, showing good bone formation and less stiffness as well. Therefore, we proposed a prospective clinical study to investigate safety, subsidence, and fusion of this prosthesis.

Locations (1)

National Taiwan University Hospital

Taipei, Taiwan