Clinical Research Directory
Browse clinical research sites, groups, and studies.
Trident Multi-tined Cannula for Cervical MBRFA Compared to the Conventional Cannula
Sponsor: University of Utah
Summary
Cervical medial branch radiofrequency ablation (CMBRFA) is an effective treatment for cervical facet pain. The efficacy of CMBRFA was proven by studies published in the late 1990's and early 2000's. Patients were selected by a strict, labor-intensive placebo-controlled, diagnostic block protocol and were treated using a conventional monopolar cannula that was positioned parallel to the medial branch, two to three lesions per medial branch nerve and both sagittal and oblique passes. Since the original CMBRFA publications, patient selection for CMBRFA is less strict, and new RFA cannulae have been developed to improve efficiency and safety while maintaining a large ablative lesion. Current clinical patient selection criteria for CMBRFA tend to be more relaxed than described in early research studies. However, subsequent research has shown that when selection criteria are too relaxed, outcomes are poorer. A recent cross-sectional study reported that when CMBRFA is done in patients selected by \>80% pain improvement after dual medial branch blocks, outcomes are similar to patients selected with a stricter selection protocol (100% pain relief) similar to the original CMBRFA studies. Although, the cross-sectional study suggests an appropriate selection criteria, it has not been used in any prospective studies. The Trident multi-tined cannula is a recent technology that produces a large ablative lesion distal to the triple-tined tip. This design allows a perpendicular/lateral approach to CMBRFA and only requires a single lesion at each medial branch. This differs from the conventional cannula, which produces it's most extensive ablative lesion along the cannula with minimal distal projection. As a result, it requires a parallel approach with multiple burn cycles at the same medial branch. The perpendicular approach with Trident and single lesion cycle at each medial branch are appealing for safety purposes and efficiency however, it's efficacy has not been directly compared to the standard conventional cannula. Problem: There are no randomized controlled trials comparing novel technologies like Trident cannula to the previously studied conventional cannula in patients selected with a more practical selection criteria. Purpose: To compared procedural characteristics, pain, and disability outcomes of CMBRFA using either a Trident or conventional cannula in patients with confirmed facet mediated pain (defined by ≥80% symptom reduction after dual medial branch block). Central Hypothesis: Trident cannula during CMBRFA will result in noninferior improvements in pain and function compared to conventional cannula but will significantly reduce procedural discomfort, time and radiation exposure. Specific Aims: 1. Determine the proportion of patients with a successful pain response (defined as ≥50% improvement in index pain) to Trident (T-CMBRFA) versus conventional (C-CMBRFA) at 3, 6, and 12 months. 2. Determine the proportion of patients with a successful functional response (defined as ≥10% reduction on neck disability index \[NDI\]) to T-CMBRFA versus C-CMBRFA at 3, 6, and 12 months. 3. Determine the proportion of patients with a successful perception of improvement (defined as a score ≥6 on the Patient Global Impression of Change \[PGIC\]) to T-CMBRFA versus C-CMBRFA at 3, 6, and 12 months.
Official title: The Effectiveness and Procedural Characteristics of the Trident Multi-tined Cannula for Cervical Medial Branch Radiofrequency Ablation Compared to the Conventional Cannula; A Multi-site, Single Blinded, Randomized Controlled Trial
Key Details
Gender
All
Age Range
18 Years - Any
Study Type
INTERVENTIONAL
Enrollment
80
Start Date
2023-04-26
Completion Date
2026-10-31
Last Updated
2025-07-01
Healthy Volunteers
No
Conditions
Interventions
Cervical Medial Branch Radiofrequency Ablation
The skin and superficial tissues will be anesthetized at each site with 1-2 mL of lidocaine. Prior to the ablation up to 2 mL of lidocaine may be used at each site to ensure adequate pain control during the ablation. Once in position, a radiofrequency ablation lesion will be made using a 30 second ramp-up time to a maximum temperature of 80 °C, followed by an additional 90 seconds at maximum temperature.
Locations (3)
University of Utah Farmington Health Center
Farmington, Utah, United States
University of Utah Orthopaedic Center
Salt Lake City, Utah, United States
University of Utah South Jordan Health Center
South Jordan, Utah, United States