Clinical Research Directory
Browse clinical research sites, groups, and studies.
Evaluating a New Sensor That Measures the Health of the Retina in Normally-sighted Subjects
Sponsor: RetMap, Inc
Summary
The primary purpose of this study is to evaluate the ability of a new contact lens electrode to record a measurable electroretinogram (ERG). ERG sensors in various forms have been in common clinical use for more than 50 years. The ERG sensor that is the subject of this study is the RM Electrode, developed by RetMap, Inc. (project sponsor). The RM Electrode is not yet approved by the FDA. The RM Electrode will be compared to other commercially available electrode The first Aim of the present study is to compare the functionality of the RM Electrode and other commercially available electrodes. Following standard ERG test protocols, responses will be recorded from ten healthy (normally-sighted) adult subjects using both electrodes (used in random order). The signal quality of the ERG responses obtained from both contact lens electrodes will be compared. Signal quality will be determined by measuring ERG signal amplitudes and calculating signal-to-noise ratios (SNR). Signal-to-noise ratios will be used to establish substantial equivalence. ERG test results will not be used to determine the effect of the devices on the participants. The second Aim of the present study is to evaluate the risk of ocular irritation caused by use of the RM Electrode compared to other commercially available electrodes. A typical ERG test session lasts 20 minutes. Ten healthy (normally-sighted) adult subjects will wear the RM Electrode on one eye and a commercially available electrode on the other eye, for a total of 60 minutes, in 20-minute sessions with short breaks in between. To determine the effect of the devices on the participants, the eyes will be evaluated for irritation.
Official title: Evaluation of an Electroretinogram Sensor
Key Details
Gender
All
Age Range
18 Years - Any
Study Type
INTERVENTIONAL
Enrollment
90
Start Date
2023-03-01
Completion Date
2025-12-31
Last Updated
2025-11-14
Healthy Volunteers
Yes
Conditions
Interventions
RM Electrode
The RM Electrode is a corneal ERG electrode. The distinguishing features of the RM electrode are that it is a soft contact lens with a recessed electrode (i.e. no metal electrode makes direct contact with the eye). The RM Electrode also has an integral speculum to hold the wearer's eye lids open. The electrode is designed for superior positional stability on the eye during testing. These features work together to improve ERG signal quality.
ERG Jet Electrode
The ERG Jet electrode is an FDA approved, commercially available corneal ERG electrode.
Locations (2)
UIC Department of Ophthalmology & Visual Sciences
Chicago, Illinois, United States
Illinois College of Optometry
Chicago, Illinois, United States