Clinical Research Directory
Browse clinical research sites, groups, and studies.
Comparative Study Between Foley and T-Control® Catheter in Patients With Long-term Catheterization
Sponsor: Rethink Medical SL
Summary
This is a comparative, randomized, controlled pilot study. The main objective of this study is to evaluate the efficacy, comfort, and patient experience in people with long-term bladder catheterization with T-Control® versus patients with a conventional Foley-type catheter.
Official title: Comparative Mixed Study of the Foley Catheter With the T-Control® Catheter in Patients With Long-term Catheterization
Key Details
Gender
All
Age Range
18 Years - Any
Study Type
INTERVENTIONAL
Enrollment
50
Start Date
2023-09-01
Completion Date
2026-12-01
Last Updated
2026-09-04
Healthy Volunteers
No
Interventions
Foley catheter
Silicone Foley catheters are transurethral balloon catheters used for the treatment of bladder emptying disorders, as well as for drainage of urine from the urinary tract, continuous fluid irrigation, and/or medication administration. Its use is suitable for a prolonged period of no more than 29 days and is used in Urology, Internal Medicine, Surgery, Obstetrics and Gynaecology Services. For this study, conventional Foley-type catheters whose use is approved in Spain for routine use will be used. Silicone Foley catheters, usually available in 2- and 3-way, are made of silicone and consist of a body, drainage funnel, inflation funnel, irrigation funnel (if present, only on 3-way catheters) and balloon valve. The product is sterile and single use.
T-Control catheter
The T-control® catheter is a flexible, sterile silicone tube with an inflatable balloon at the distal tip, a polytetrafluroethylene membrane integrated into its body, and a sliding fluid control valve. The valve, built into the catheter, provides additional functions to the catheter, such as turning urine flow on and off after insertion (functions currently provided by accessories such as caps or valves) and controlling urination during the insertion process (function that is not provided by any other device). In this way, accidental loss of urine can be avoided from the first moment of use until its withdrawal. Additionally, it has a safety cap that reduces the possibility of accidental movements of the valve before use or during transport and fixing. The design has been developed in such a way that, once inserted, it facilitates autonomous use even for the elderly or patients with limited manual dexterity. The device is sterile and single use, like any conventional Foley catheter.
Locations (2)
Hospital Universitario de Canarias
Santa Cruz de Tenerife, Tenerife, Spain
Hospital Universitario 12 de Octubre
Madrid, Spain