Clinical Research Directory
Browse clinical research sites, groups, and studies.
Ablate and Pace HIS Study
Sponsor: University Hospitals, Leicester
Summary
Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia, and estimates suggest its prevalence is increasing. Despite the advances in AF ablation strategies, the outcome of ablation procedures in persistent AF is still unsatisfactory. In addition, many patients are not candidates for ablation due to advanced age, comorbidities and previous failed ablation procedures. It is well known that there is no mortality benefit from rhythm versus rate control strategy in AF, therefore the increased number of AV node ablation and pacemaker insertion for patients with symptomatic AF with uncontrolled heart rate. Following AV node ablation, it is understandable that these patients will be paced 100% of the time where the value of physiological pacing will be at its most. The current standard practice is to pace the right ventricle for this cohort of patients unless they have severe LV systolic dysfunction when a biventricular pacing might be recommended. Previous data showed that RV pacing only can lead to deterioration of LV function, worsening of heart failure symptoms and increased mortality. HIS bundle pacing is a novel technique of pacing through placing the pacemaker lead on the junction box between the top and bottom chamber of the heart. This will allow the utilisation of the normal/intrinsic HIS Purkinjie (eclectic cables) to stimulate the ventricles. This can offer a physiological pacing modality and reduce pacing induced cardiomyopathy specially in pacing dependent pacing. The Ablate and Pace HIS Study proposes that the new method of HIS pacing is safe, effective and superior to the existing method of RV pacing in patients with atrial fibrillation who demonstrate signs of heart failure.
Official title: Safety and Efficacy of Distal His Bundle Pacing Compared to Right Ventricular Pacing in Patients With Symptomatic Atrial Fibrillation Undergoing AV Node Ablation With Evidence of Heart Failure, a Randomised Control Study
Key Details
Gender
All
Age Range
18 Years - 100 Years
Study Type
INTERVENTIONAL
Enrollment
100
Start Date
2023-10-24
Completion Date
2028-02-29
Last Updated
2026-01-05
Healthy Volunteers
No
Conditions
Interventions
Ablation and Pacemaker Implantation
All patients will be implanted with a pacemaker device with one lead positioned in right ventricle (control arm only) and an additional lead will be positioned on the distal (ventricular) HIS bundle if in intervention arm. All patients will undergo ablation.
Locations (1)
University Hospitals of Leicester NHS Trust
Leicester, Leicestershire, United Kingdom