Tundra Space

Tundra Space

Clinical Research Directory

Browse clinical research sites, groups, and studies.

Back to Studies
RECRUITING
NCT06303960
EARLY_PHASE1

Cerebellar Deep Brain Stimulation or VNS for Chronic Post-stroke Motor Rehabilitation

Sponsor: Qilu Hospital of Shandong University

View on ClinicalTrials.gov

Summary

Upper-extremity impairment after stroke remains a major therapeutic challenge and a target of neuromodulation treatment efforts.In this open-label, randomized phase I trial, we applied deep brain stimulation to the cerebellar dentate nucleus combined with bilateral or unilateral stimulation. Vagus nerve stimulation was also conducted for motor function after ischaemic Stroke.We hypothesized that cerebellar stimulation was superior to vagus stimulation as the motor rehabilitation after stroke benefits from both side of cerebellum.

Official title: The Comparison of Treatment Results Between Cerebellar DBS and Vagus Stimulation for Post-stroke Motor Rehabilitation: a Randomized Clinical Trial

Key Details

Gender

All

Age Range

30 Years - 75 Years

Study Type

INTERVENTIONAL

Enrollment

100

Start Date

2024-03-15

Completion Date

2026-03-07

Last Updated

2025-04-17

Healthy Volunteers

No

Conditions

Interventions

DEVICE

Bilateral Cerebellar deep brain stimulation

Participants underwent stereotactic implantation of a single DBS lead in the area of the cerebellar DN contralateral to the lesioned cerebral hemisphere using a frame-based technique similar to that used in DBS for movement disorders. All participants received an 4-channel lead (Medtronic,3389)with electrode arrays up to 15.5 mm in length. Then bilateral stimulation was activated after 1 month post-DBS

DEVICE

Unilateral Cerebellar deep brain stimulation

Participants underwent stereotactic implantation of a single DBS lead in the area of the cerebellar DN contralateral to the lesioned cerebral hemisphere using a frame-based technique similar to that used in DBS for movement disorders. All participants received an 4-channel lead (Medtronic,3389)with electrode arrays up to 15.5 mm in length. Then unilateral stimulation was activated after 1 month post-DBS

DEVICE

Vagus Nerve Stimulation

Device implantation was done under general anaesthesia. A horizontal neck crease incision was created left of the midline at the level of the cricoid cartilage. After the vagus nerve was identified, the stimulation lead was wrapped around the vagus nerve. The lead was then tunnelled subcutaneously to the pulse generator device which was contained in a subcutaneous pocket in the pectoral region.

Locations (1)

Chao Zhang

Jinan, Shandong, China