Clinical Research Directory
Browse clinical research sites, groups, and studies.
The Effect of SRS on Hemiplegia in Stroke Survivors
Sponsor: Virginia Commonwealth University
Summary
Strokes are one of the leading causes of long term disability and death in the United States. A stroke occurs when the blood supply to the brain is blocked, damaging parts of the brain. Many stroke survivors have difficulty completing dexterous hand movements and manipulating objects due brain damage in the sensorimotor cortex. Damage to these areas can cause decreased motor movements and tactile sensation on the affected side. Research shows that tactile sensation is necessary for maintaining grip, grading grip forces and decreasing object slippage. Therefore, it is important to address tactile sensation with motor performance during stroke rehabilitation to improve performance outcomes among stroke survivors.
Official title: The Effect of SRS on Hemiplegia in Stroke Survivors: A Feasibility Study
Key Details
Gender
All
Age Range
18 Years - Any
Study Type
INTERVENTIONAL
Enrollment
20
Start Date
2024-03-04
Completion Date
2027-02
Last Updated
2026-05-11
Healthy Volunteers
No
Conditions
Interventions
Sensory Threshold
Using a light, vibrotactile noise device on the participant's affected wrist. The actuator will be positioned on both the dorsal and volar sides of the wrist. Each participant's sensory threshold will be measured using the method of ascending and descending limits
Nine Hole Peg Test
The Nine-Hole Peg Test (NHPT) is considered as a gold standard measure of manual dexterity and most frequently used in MS research and clinical practice. The score for the 9-HPT is an average of the four trials. The two trials for each hand are averaged, converted to the reciprocals of the mean times for each hand and then the two reciprocals are averaged. On average, healthy male adults complete the NHPT in 19.0 seconds (SD 3.2) with the right hand, and in 20.6 seconds (SD 3.9) with the left hand.
Semmes Weinstein Monofilament Assessment
A non-invasive, low-cost, simple, and accurate handheld calibrated nylon thread that buckles once it has delivered a force of 10 g. It provides a standardized measure of a patient's ability to sense a point of pressure. The filaments are classified from grade 1 to 5 according to their thickness: 1.65-2.83 = grade 5, 3.22-3.61 = grade 4, 3.84-4.31 = grade 3, 4.56-6.45 = grade 2, and 6.65 = grade 1.
Locations (1)
Virginia Commonwealth University
Richmond, Virginia, United States