The External Diaphragm Pacemaker Assisted Extubation in Premature Infants With Invasive Mechanical Ventilation

Sponsor: Children's Hospital of Chongqing Medical University

View on ClinicalTrials.gov

Summary

With the development of perinatal medicine, more and more newborns with respiratory failure can be treated due to the use of respiratory support technology. However, long-term invasive mechanical ventilation treatment can lead to a series of complications such as ventilator-associated pneumonia, atelectasis and air leakage syndrome, and increase the risk of bronchopulmonary dysplasia and neurodevelopmental lag of premature infants. It also leads to longer hospital stays and higher hospital costs. To shorten the invasive mechanical ventilation time and improve the success rate of withdrawal through various ways is the development direction of neonatal mechanical ventilation therapy. Respiratory muscle atrophy is common and rapid in children receiving invasive mechanical ventilation, and is an important cause of ventilator dependence and withdrawal failure. The diaphragm of newborns is the main respiratory muscle, of which the diaphragm type 1 endurance fiber accounts for only about 30%, far lower than the proportion of about 55% in adults, so the diaphragm of newborns is more prone to fatigue. Previous animal experiments and clinical studies in children and adults have confirmed that diaphragmatic pacing therapy applied to patients with long-term invasive mechanical ventilation can prevent diaphragmatic atrophy, reverse diaphragmatic injury, significantly improve diaphragmatic thickness, improve diaphragmatic anti-fatigue ability, thereby increasing lung ventilation, relieving dyspnea, and achieving the effect of assisted extubation. The neonatology Department of the Children's Hospital Affiliated to Chongqing Medical University started neonatal external diaphragm pacemaker treatment in 2022, and has completed 1383 cases so far, initially showing the effectiveness and safety of external diaphragm pacemaker treatment in neonatal population. But so far, there is no systematic evaluation of clinical intervention effect of external diaphragm pacemaker treatment on neonatal respiratory failure patients at home and abroad. Based on this, the project team intends to conduct a prospective randomized controlled study to systematically evaluate the safety of external diaphragm pacemaker in preterm infants requiring invasive mechanical ventilation for ≥7 days at 28 to 35 weeks of gestation, and to evaluate the efficacy of external diaphragm pacemaker in adjuvant extubation.

Official title: A Randomized Controlled Study of the External Diaphragm Pacemaker Assisted Extubation in Premature Infants With Invasive Mechanical Ventilation

Key Details

Gender

All

Age Range

1 Day - 3 Months

Study Type

INTERVENTIONAL

Enrollment

40

Start Date

2024-03-31

Completion Date

2024-12-31

Last Updated

2024-05-08

Healthy Volunteers

No

Interventions

DEVICE

External Diaphragm Pacemaker treatment

On the basis of conventional treatment, the patients in this group were treated with external diaphragm pacemaker for 2 weeks or until extubation.The treatment process of external diaphragm pacemaker is as follows: Set parameters: pacing frequency: 5-9 times /min, generally starting from 5 times /min, and adjusted according to the tolerance of the child; Pulse frequency 30 hertz; The stimulation intensity generally starts from 2-3. If the respiratory waveform of the child on the machine is not disturbed, it indicates that the child can tolerate it and the intensity can be appropriately increased. Treatment time: generally starts from 5 minutes, the longest is not more than 20 minutes, the frequency of treatment: 1 time/day in the first week, 2 times/day in the second week.