Clinical Research Directory
Browse clinical research sites, groups, and studies.
Bidirectional Tuning of the AFO Stiffness
Sponsor: Academisch Medisch Centrum - Universiteit van Amsterdam (AMC-UvA)
Summary
The goal of this pilot study with a pre-post design is to investigate the effects of separate individualization of the AFO stiffness towards plantar- and dorsiflexion in a spring-hinged AFO on walking compared to a spring-like AFO (3 types) having the same stiffness in both directions. People with a neuromuscular disease or nerve injury causing at least plantarflexor weakness (determined as the inability to perform 3 single heel rises), with an indication for or using an AFO, will be fitted with a new, custom-made spring-hinged AFO with the NEURO SWING® system ankle joint (Fior\& Gentz, Lüneburg, Germany), of which the stiffness of ventral and dorsal compartment of this spring-hinged AFO will be individualized. For comparison, measurements will be performed with three different prefab spring-like AFOs with different stiffness levels (but which have a similar stiffness towards plantar and dorsiflexion), and the participants' current AFO if applicable, and shoes-only at baseline. The main outcome parameters will be the maximal ankle plantarflexion angle, ankle angular velocity and knee flexion angle during the loading response, which will be measured using a 3D gait analysis. Secondary outcomes include other gait biomechanics, walking energy cost, walking speed, standing balance, perceived physical functioning and perceived walking ability.
Official title: Optimizing Gait with Bidirectional Tuning of the Ankle-foot Orthosis (AFO) Stiffness in People with Lower Leg Muscle Weakness
Key Details
Gender
All
Age Range
18 Years - Any
Study Type
INTERVENTIONAL
Enrollment
10
Start Date
2024-05-15
Completion Date
2025-02-01
Last Updated
2025-02-05
Healthy Volunteers
No
Conditions
Interventions
NEURO SWING AFO (Fior& Gentz, Lüneburg, Germany)
stiffness-optimized custom-made spring-hinged AFO with the NEURO SWING® system ankle joint build in
WalkOn Reaction® (Ottobock, Duderstadt)
comparator: prefab spring-like AFO without hinge with a predefined stiffness (2.8 Nm/degree).
Matrix Max2® (TruLife, Dublin, Ireland)
comparator: prefab spring-like AFO without hinge with a predefined stiffness (1.4 Nm/degree)
Matrix® (TruLife, Dublin, Ireland)
comparator: prefab spring-like AFO without hinge with a predefined stiffness (0.6 Nm/degree)
Locations (1)
Department of rehabilitation medicine Amsterdam UMC, location AMC
Amsterdam, Netherlands