Tundra Space

Tundra Space

Clinical Research Directory

Browse clinical research sites, groups, and studies.

Back to Studies
ACTIVE NOT RECRUITING
NCT06513299

Effectiveness of Low Volume and Low Pressure in Severe Hypoxemic Patients

Sponsor: Gruppo Italiano per la Valutazione degli Interventi in Terapia Intensiva

View on ClinicalTrials.gov

Summary

The present study set up to answer two questions: (a) "how low tidal volume must be to provide protective ventilatory settings able to minimize the risk of death due to Ventilator-Induced Lung Injury (VILI)?"; (b) "if protection from VILI is better achieved by targeting the driving pressure instead of the tidal volume, what is the optimal target for the driving pressure?". Solving these questions is pivotal for clinicians to personalized and precise mechanical ventilation practices to reduce the risk of VILI and avoid unnecessary risks associated to protective ventilatory settings. Two multicenter emulated target trials will be performed using data collected with the Electronic Health Record MargheritaTre, to investigate the effect of low tidal volumes (6.0 to 8.0 ml/kg PBW vs 8.0 to 10.0 ml/kg PBW) and low driving pressures (7.0-12.0 cmH2O vs 12.0-18.0 cmH2O), respectively. Data will be used to obtain the dose-response curve of lower VT and lower ∆P in mechanically ventilated patients with acute severe hypoxemia.

Official title: Assessing the Effectiveness of Low Tidal Volume and Low Driving Pressure in Mechanically Ventilated Severe Hypoxemic Patients: a Multicenter Emulated Target Trial

Key Details

Gender

All

Age Range

18 Years - Any

Study Type

OBSERVATIONAL

Enrollment

4300

Start Date

2024-12-24

Completion Date

2025-12-31

Last Updated

2024-12-27

Healthy Volunteers

No

Conditions

Interventions

DEVICE

low tidal volume

Patients ventilated with assist/control modes of mechanical ventilation with tidal volume between 6.0 ml/kg PBW and 8.0 ml/kg PBW with PPLAT ≤ 30 cmH2O, until weaning criteria are met: P/F ratio \> 250 mmHg; PEEP ≤ 8 cmH2O and lower than the previous day; FiO2 \< 0.5 and lower than the previous day; systolic arterial pressure ≥ 85 mmHg.

DEVICE

high tidal volume

Patients ventilated with assist/control modes of mechanical ventilation with tidal volume between 8.0 ml/Kg PBW and 10.0 ml/kg PBW with PPLAT ≤ 30 cmH2O, until weaning criteria are met: P/F ratio \> 250 mmHg; PEEP ≤ 8 cmH2O and lower than the previous day; FiO2 \< 0.5 and lower than the previous day; systolic arterial pressure ≥ 85 mmHg.

DEVICE

low driving pressure

Patients ventilated with assist/control modes of mechanical ventilation with driving pressure between 7.0 cmH2O and 12.0 cmH2O with VT ≤ 10 ml/kg PBW, until weaning criteria are met: P/F ratio \> 250 mmHg; PEEP ≤ 8 cmH2O and lower than the previous day; FiO2 \< 0.5 and lower than the previous day; systolic arterial pressure ≥ 85 mmHg.

DEVICE

high driving pressure

Patients ventilated with assist/control modes of mechanical ventilation with driving pressure between 12.0 cmH2O and 18.0 cmH2O with VT ≤ 10 ml/kg PBW, until weaning criteria are met: P/F ratio \> 250 mmHg; PEEP ≤ 8 cmH2O and lower than the previous day; FiO2 \< 0.5 and lower than the previous day; systolic arterial pressure ≥ 85 mmHg.

Locations (1)

Mario Negri Institute for Pharmacological Research IRCCS

Ranica, BG, Italy