Tundra Space

Tundra Space

Clinical Research Directory

Browse clinical research sites, groups, and studies.

Back to Studies
ACTIVE NOT RECRUITING
NCT06595498
NA

Next Generation Sequencing Method for the Detection of EGFR Gene Mutations in the Plasma of Patients With Lung Cancer

Sponsor: Istituto Oncologico Veneto IRCCS

View on ClinicalTrials.gov

Summary

The study aims to evaluate the Plasma-SeqSensei™ Solid Cancer IVD Kit NGS diagnostic test (Sysmex) before its introduction into routine diagnostics. This is a test for research of EGFR mutations in cfDNA that needs to be evaluated in a patient population with lung adenocarcinoma already characterized for EGFR mutations by a molecular test of reference. The proposed study does not present any risk to participants.

Official title: Evaluation of an Ultrasensitive Next Generation Sequencing Method for the Detection of EGFR Gene Mutations in the Plasma of Patients With Lung Cancer

Key Details

Gender

All

Age Range

18 Years - Any

Study Type

INTERVENTIONAL

Enrollment

130

Start Date

2024-07-01

Completion Date

2026-06-30

Last Updated

2026-03-02

Healthy Volunteers

No

Interventions

DIAGNOSTIC_TEST

Plasma- SeqSensei™ Solid Cancer IVD Kit (Sysmex)

The patients' blood has already been collected in Streck tubes for circulating DNA and the plasma has been stored at -80°C as per the procedure for the routine diagnostic test cobas EGFR Mutation Test v2. No further blood sampling will be required from patients. Circulating DNA/RNA will be extracted from 2-5 ml of plasma. The extracted cfDNA will be quantified. The libraries will be prepared using the NGS Plasma-SeqSensei™ Solid Cancer IVD Kit (Sysmex) and will be evaluated at the Tapestation (Agilent) to verify their quality and quantity using D1000 Screentapes. The libraries consisting of approximately 16 samples each will then be sequenced on an Illumina NextSeq 500 sequencer using the Illumina NextSeq 500/550 Mid Output Kit v2.5 (150 Cycles). Data analysis will be performed using Plasma-SeqSensei™ IVD Software (Sysmex).

DIAGNOSTIC_TEST

cobas® EGFR Mutation Test v2 (Roche)

The patients' blood has already been collected in Streck tubes for circulating DNA and the plasma has been stored at -80°C as per the procedure for the routine diagnostic test cobas EGFR Mutation Test v2. No further blood sampling will be required from patients. Circulating DNA/RNA will be extracted from 2-5 ml of plasma. The extracted cfDNA will be quantified. The libraries will be prepared using the cobas® EGFR Mutation Test v2 (Roche) and will be evaluated at the Tapestation (Agilent) to verify their quality and quantity using D1000 Screentapes. The libraries consisting of approximately 16 samples each will then be sequenced on an Illumina NextSeq 500 sequencer using the Illumina NextSeq 500/550 Mid Output Kit v2.5 (150 Cycles).

Locations (1)

Istituto Oncologico Veneto

Padova, Italy