Tundra Space

Tundra Space

Clinical Research Directory

Browse clinical research sites, groups, and studies.

Back to Studies
RECRUITING
NCT06601322
NA

Functional Outcomes in CondUction System Pacing and Right Ventricular Synchrony (FOCUS-Right)

Sponsor: Virginia Commonwealth University

View on ClinicalTrials.gov

Summary

The goal of this prospective single center clinical trial is to evaluate the safety and feasibility of performing simultaneous exercise stress cardiac magnetic resonance (CPET-CMR) and cardiopulmonary exercise testing in patients with pre-existing left bundle branch area pacemakers (LBBAP) programmed to an atrial sensing mode. Measurements of right ventricular, left ventricular function, and exercise capacity will be obtained at various LBBAP programming parameters at rest and during low intensity exercise. The main aims of the study are: * Demonstrate the safety and feasibility of performing CPET-CMR in patients with pre-existing LBBAP programmed to P-synchronous ventricular pacing mode. * Generate preliminary data evaluating differences in RV function, LV function, and exercise capacity during various pacemaker programming settings.

Official title: Functional Outcomes in CondUction System Pacing and Right Ventricular Synchrony The FOCUS-Right Pilot Study (FOCUS-Right)

Key Details

Gender

All

Age Range

18 Years - Any

Study Type

INTERVENTIONAL

Enrollment

20

Start Date

2024-08-23

Completion Date

2026-03

Last Updated

2026-01-22

Healthy Volunteers

No

Interventions

OTHER

Pacemaker Interrogation and Electrocardiogram (ECG):

Prior to the CMR study, subjects will undergo baseline interrogation of their dual chamber LBBAP to assess for appropriate device function. Lead capture characteristics will then be assessed with continuous intracardiac electrogram characteristics recorded from the atrial and ventricular lead with simultaneous 12-lead ECG rhythm strip recordings to assess for settings at which the investigators can differentiate aLBBAP, sLBBAP and nsLBBAP. Pacing output will be increased until left bundle branch area pacing with anodal capture is achieved, and then decreased until anodal capture is lost. These programming parameters will be recorded and utilized for Phase 2-3 of the CPET-CMR scan. 12-lead ECG rhythm strips of QRS morphology with each parameter set will be obtained and saved for later analysis.

OTHER

Cardiopulmonary Exercise Test (CPET) and Exercise Stress Cardiac Magnetic Resonance (ExeCMR

Following ECG and pacemaker analysis as above for safety, subjects will be fitted with 2 sets of MRI-compatible ECG monitoring systems a BP monitoring system , and a finger-tip pulse gating system. Imaging will be performed on a Magnetom Vida 3 Tesla scanner by trained CRM radiology technologists.

OTHER

Continuous pacemaker telemetry (CPT)

CPT will be established and supervised by a cardiac electrophysiologist to monitor for evidence of noise or artifact which may lead to inability to appropriately sense native atrial depolarization in DDD mode. Subjects with PM dependence are excluded. If noise is noted during scanning with NVP, then scanning will NOT be performed during P-synchronous pacing and will instead be performed during overdrive pacing at a rate above the patients maximal achieved heart rate with exertion during Phase 1. Thus, there is minimal risk to the subject from PM programming during CPET-CMR.

Locations (1)

Virginia Commonwealth University

Richmond, Virginia, United States