Hemodynamic Response to the End-expiratory Occlusion Test to Titrate Fluid Challenge in Operating Room.

Sponsor: Humanitas Clinical and Research Center

View on ClinicalTrials.gov

Summary

Personalzing intraoperative anesthetic fluid management may help in preventing fluid accumulation and related complications. Fluids are gine as boluses in operating room (the so-called FC). The response to the FC is due to several physiological conditions related to the "preload dependency" (i.e. the intrinsic ability of the heart of increasing the stroke volume - SV - in response to fluid administration). The minimal volume required to appropriately "challenge" the cardiovascular system is 4 ml/kg of fluid, but higher volumes (up to 6 ml/kg may be needed). Predicting the response to FC administration may be possible by applying a physiological test (called functional hemodynamic test), such as the end-expiratory occlusion test, consisting in interrupping the mechanical ventilation and hence promoting venous return and consequente SV changes. The percentage of SV increase associated to EEOT may predict fluid responsiveness to the FC (patients responders will increase SV to a bigger extent, as compared to non-responders)

Key Details

Gender

All

Age Range

18 Years - Any

Study Type

OBSERVATIONAL

Enrollment

300

Start Date

2024-11-01

Completion Date

2026-09-01

Last Updated

2024-10-08

Healthy Volunteers

No

Interventions

OTHER

fluid challenge

The study protocol is started during a period of intraoperative hemodynamic stability, as previously defined (i.e. change in mean arterial pressure of less than 10% during 5 minutes \[32, 33\]). The study protocol is was the following: 1) a set of measurements was recorded (T0) at a baseline 2) (T1) after one minute the EEOT is then performed by stopping the mechanical ventilation for 30 seconds (T2 - end of the EEOT test); 3) (T3) a FC of overall 6 mL/Kg of crystalloid solution is infused over 10 minutes (T4 end of the FC). The attending anesthetist is allowed to interrupt the protocol at any stage for either hemodynamic instability or any other adverse effects requiring urgent treatment. The protocol is entirely intraoperative and data collections ends after FC administration. No follow-up is needed. The mentioned timepoints T0 - T1 - T2, corresponding to intrapeortive data recording points are also the endpoints of the study. At each specific timepoint, a marker is added to the M

DIAGNOSTIC_TEST

end-expiratory occlusion test

The study protocol is started during a period of intraoperative hemodynamic stability, as previously defined (i.e. change in mean arterial pressure of less than 10% during 5 minutes \[32, 33\]). The study protocol is was the following: 1) a set of measurements was recorded (T0) at a baseline 2) (T1) after one minute the EEOT is then performed by stopping the mechanical ventilation for 30 seconds (T2 - end of the EEOT test); 3) (T3) a FC of overall 6 mL/Kg of crystalloid solution is infused over 10 minutes (T4 end of the FC). The attending anesthetist is allowed to interrupt the protocol at any stage for either hemodynamic instability or any other adverse effects requiring urgent treatment. The protocol is entirely intraoperative and data collections ends after FC administration. No follow-up is needed. The mentioned timepoints T0 - T1 - T2, corresponding to intrapeortive data recording points are also the endpoints of the study. At each specific timepoint, a marker is added to the M