Tundra Space

Tundra Space

Clinical Research Directory

Browse clinical research sites, groups, and studies.

Back to Studies
RECRUITING
NCT06642753
NA

Buccal Plate Augmentation Using Sticky Bone With Simultaneous Immediate Implant Placement

Sponsor: Cairo University

View on ClinicalTrials.gov

Summary

the aim of this study is to clinically assess pink esthetic score following Buccal Plate Augmentation using Sticky Bone versus usage of Sticky Bone as a jumping gap filling material with simultaneous immediate implant placement in the maxillary esthetic zone

Official title: Buccal Plate Augmentation Using Sticky Bone Versus Usage of Sticky Bone as a Jumping Gap Filling Material With Simultaneous Immediate Implant Placement in the Maxillary Esthetic Zone :A Randomized Controlled Clinical Trial

Key Details

Gender

All

Age Range

18 Years - Any

Study Type

INTERVENTIONAL

Enrollment

20

Start Date

2024-06-01

Completion Date

2025-05

Last Updated

2024-10-23

Healthy Volunteers

Yes

Interventions

BIOLOGICAL

immediate implant with buccal plate augmentation using sticky bone

* Venous blood will be withdrawn and transferred into sterile tubes which will be devoid of anticoagulants. I- PRF preparation will be done using the protocol developed by Mourãoet al. * Plastic PET tubes to create Liquid-PRF, while glass tubes will be used to obtain Solid-PRF. * Blood will be centrifuged at a speed of 3000 rpm for 10 minutes to obtain autologous PRF plug. * Blood will be centrifuged at a speed of 700 rpm for 3 minutes. An orange- colored fluid will be formed as the upper layer in the test tubes i.e., I- PRF. Approximately 1 ml of I-PRF will be collected in a syringe. * Solid-PRF + Liquid-PRF mixed DBBM: Solid-PRF membranes will be mixed thoroughly with 0.25 g of DBBM particles. Then 1 mL Liquid PRF from the buffy coat layers will be added drop by drop to the DBBM. * Following polymerization by 15-20 minutes, sticky bone will be ready to be grafted in the pouch .

BIOLOGICAL

immediate implant with sticky bone as a filling material in the jumping gap

Venous blood will be withdrawn and transferred into sterile tubes which will be devoid of anticoagulants. I- PRF preparation will be done using the protocol developed by Mourãoet al. * Plastic PET tubes to create Liquid-PRF, while glass tubes will be used to obtain Solid-PRF. * Blood will be centrifuged at a speed of 3000 rpm for 10 minutes to obtain autologous PRF plug. * Blood will be centrifuged at a speed of 700 rpm for 3 minutes. An orange- colored fluid will be formed as the upper layer in the test tubes i.e., I- PRF. Approximately 1 ml of I-PRF will be collected in a syringe. * Solid-PRF + Liquid-PRF mixed DBBM: Solid-PRF membranes will be mixed thoroughly with 0.25 g of DBBM particles. Then 1 mL Liquid PRF from the buffy coat layers will be added drop by drop to the DBBM. * Following polymerization by 15-20 minutes, sticky bone will be ready to be grafted in the jumping gap.

Locations (1)

Faculty of Dentistry Cairo University