Tundra Space

Tundra Space

Clinical Research Directory

Browse clinical research sites, groups, and studies.

Back to Studies
NOT YET RECRUITING
NCT06675045
NA

Respiratory Variability in Patients With Acute Hypoxemic Respiratory Failure and Placed on High Flow Oxygen Therapy

Sponsor: GCS Ramsay Santé pour l'Enseignement et la Recherche

View on ClinicalTrials.gov

Summary

Recommendations from the European Respiratory Society are to use high-flow oxygen therapy rather than conventional oxygen therapy and non-invasive ventilation (NIV) in cases of acute hypoxaemic respiratory failure. Studies have shown that high-flow oxygen therapy can reduce the need for intubation and the initiation of NIV without reducing mortality. In addition, by improving oxygenation, high-flow oxygen therapy can create a feeling of security which may delay endotracheal intubation. Two studies have suggested that mortality is higher in patients receiving delayed intubation (≥ 48 hours) after failure of high flow oxygen therapy. Another study suggests that delayed endotracheal intubation after high-flow oxygen therapy ≥ 48 hours increases the risk of patient mortality independently of comorbidities and severity of illness on admission. Finally, other results suggest that the increased risk of mortality may be significant after 36 hours of high-flow oxygen therapy. It is therefore difficult to determine the right time for intubation and invasive ventilation. A diagnostic decision aid could be of great use to the attending physician in optimising the patient's respiratory assistance strategy, whether invasive or non-invasive. Consequently, any clinical marker that can provide early detection of altered respiratory status on high-flow oxygen therapy deserves to be evaluated. Respiratory variability is synonymous with respiratory 'good health'. A decrease in this same variabilitý is pathological and indicates an increase in the level of loads imposed on the respiratory system. It means that the measurement of respiratory variability indices may be one of these markers There are devices for non-invasive, continuous monitoring of respiratory variability, with automated frequency analysis of thoracic movement. In this study, respiratory variability indices will be measured in patients admitted to intensive care under high-flow oxygen therapy using an external sensor called REVAMODE.

Official title: Description of Respiratory Variability in Patients With Acute Hypoxemic Respiratory Failure and Placed on High Flow Oxygen Therapy - Exploratory Study

Key Details

Gender

All

Age Range

18 Years - Any

Study Type

INTERVENTIONAL

Enrollment

60

Start Date

2025-12-01

Completion Date

2026-06-30

Last Updated

2025-11-19

Healthy Volunteers

No

Interventions

OTHER

Respiratory variability monitoring

Respiratory variability will be measured using a belt equipped with an external sensor allowing automatic and continuous analysis of thoracic movement by frequency analysis