Tundra Space

Tundra Space

Clinical Research Directory

Browse clinical research sites, groups, and studies.

Back to Studies
ACTIVE NOT RECRUITING
NCT06702540

Bio-reconfigurable Electronic Platform for Multiplex Detection of Viral Respiratory Pathogens

Sponsor: IRCCS San Raffaele

View on ClinicalTrials.gov

Summary

This project focuses on developing a cutting-edge electronic biosensor platform for highly sensitive and specific detection of target biomolecules, with initial applications targeting SARS-CoV-2 detection. The system operates on impedance measurement between microelectrodes, utilizing lock-in mode for unparalleled resolution (1 ppm). Enhanced signal detection is achieved via functionalized polystyrene microbeads that amplify impedance changes, building on prior success in Dengue virus antibody detection. Key innovations include Differential Impedance Sensing across multiple channels for real-time comparative analysis of various targets, and a biosensor chip modified with DMA-based functional polymers for optimal probe immobilization and target interaction. The biosensor integrates with a pre-existing microfluidic system and supports whole-virus detection using DNA-labelled antibodies against SARS-CoV-2 spike protein, coupled with complementary oligonucleotide-functionalized beads. This strategy is complemented by antigen-specific detection for practical applications such as point-of-care testing in pharmacies. The project includes a retrospective study analyzing anonymized respiratory and plasma samples from a COVID-19 biobank to validate the platform's sensitivity in detecting viral particles. These efforts aim to advance diagnostic technologies for respiratory infections with a focus on safety, scalability, and versatility.

Official title: Bio-reconfigurable Differential Impedance Electronic Platform for High Sensitivity Multiplex Detection of Viral Respiratory Pathogens

Key Details

Gender

All

Age Range

Any - Any

Study Type

OBSERVATIONAL

Enrollment

158

Start Date

2020-03-19

Completion Date

2025-09-28

Last Updated

2024-11-25

Healthy Volunteers

Yes

Conditions

Interventions

DEVICE

Biosensor chip

An electronic platform measuring the impedance variation between microelectrodes is used upon capturing the target biomolecule by a selective bioprobe previously grafted over the biosensor surface. The required sensitivity will be achieved by operating the biosensor in lock-in mode, which ensures the highest resolution in tracking amplitude and phase variations of impedance signals.

Locations (1)

IRCCS San Raffaele

Milan, Italy, Italy