Clinical Research Directory
Browse clinical research sites, groups, and studies.
TAES Alleviate Post-VATS Depression
Sponsor: Fuling Central Hospital of Chongqing City
Summary
Depression can significantly affect postoperative rehabilitation quality and increase the mortality of patients who receive video-assisted thoracoscopic surgery (VATS). This study intend to evaluate the transcutaneous electrical acupoint stimulation (TEAS) of VATS safety and the efficacy of the postoperative depression compared to a sham group.
Official title: Transcutaneous Electrical Acupoint Stimulation Alleviate Postoperative Depression in Video-assisted Thoracoscopic Surgery: a Randomized Controlled Trial
Key Details
Gender
All
Age Range
18 Years - 65 Years
Study Type
INTERVENTIONAL
Enrollment
120
Start Date
2024-12-20
Completion Date
2026-03-10
Last Updated
2024-12-05
Healthy Volunteers
No
Interventions
Transcutaneous electrical acupoint stimulation
After entering the operating room, an experienced traditional Chinese medicine doctor will locate the bilateral Shenmen, Neiguan, Hegu, Chize, and Anmian acupoints, and sham acupoints. The target treatment acupoints will be wiped with 75% ethanol, and after the ethanol had evaporated, electrode pads (50 × 50 mm) will be placed and fixed according to the different groups. Thirty minutes before anesthesia, a TAES stimulator (Hwato Electronic Acupuncture Treatment Instrument, model no: SDZ-III; Suzhou Medical Appliances Co. Ltd, Suzhou, China) will be connected with a frequency setting of 2/10 Hz (2 Hz for 10 s and 10 Hz for 5 s), in dense-disperse mode. The current intensity will be set according to the patient's maximum tolerance and muscle twitching and continued until the end of the surgery.
Sham-TAES
After entering the operating room, an experienced traditional Chinese medicine doctor will locate the bilateral sham acupoints. The Sham acupoints is 4 cm interior to the bilateral Shenmen, Neiguan, Hegu, Chize, and Anmian acupoints. The sham acupoints will be wiped with 75% ethanol, and after the ethanol had evaporated, electrode pads (50 × 50 mm) will be placed and fixed according to the different groups. Thirty minutes before anesthesia, a TAES stimulator (Hwato Electronic Acupuncture Treatment Instrument, model no: SDZ-III; Suzhou Medical Appliances Co. Ltd, Suzhou, China) will be connected with a frequency setting of 2/10 Hz (2 Hz for 10 s and 10 Hz for 5 s), in dense-disperse mode. The current intensity will be set according to the patient's maximum tolerance and muscle twitching and continued until the end of the surgery
Locations (1)
Fuling Central Hospital of Chongqing
Fuling, Chongqing Municipality, China