Tundra Space

Tundra Space

Clinical Research Directory

Browse clinical research sites, groups, and studies.

Back to Studies
COMPLETED
NCT06871020
NA

Periodontal Health and Patient Satisfaction of CAD/CAM Fiber-Reinforced vs. PFM Attachments in Distal Extension RPDs

Sponsor: Ain Shams University

View on ClinicalTrials.gov

Summary

This randomized clinical trial aims to assess periodontal health and patient satisfaction in mandibular distal extension removable partial dentures using CAD/CAM fiber-reinforced composite versus porcelain-fused-to-metal extracoronal attachments. Twenty-four participants with bilateral mandibular Kennedy Class I, retaining only the canines and first premolars as the last standing abutments bilaterally, will be randomly assigned to two groups. Group I (n=12) will receive OT extracoronal attachments made from CAD/CAM fiber-reinforced composite, while Group II (n=12) will receive OT extracoronal attachments made from porcelain-fused-to-metal. All participants will then receive a metallic removable partial denture. The null hypothesis states that no significant differences will be observed in periodontal health and patient satisfaction between the two attachment types.

Official title: Evaluation of Periodontal Health and Patient Satisfaction of CAD/CAM Fiber-Reinforced Composite Versus Porcelain Fused to Metal Extracoronal Attachment in Mandibular Distal Extension Removable Partial Dentures: A Randomized Clinical Trial

Key Details

Gender

All

Age Range

20 Years - Any

Study Type

INTERVENTIONAL

Enrollment

24

Start Date

2025-01-01

Completion Date

2026-03-15

Last Updated

2026-10-13

Healthy Volunteers

Yes

Interventions

OTHER

Mandibular removable partial denture retained on OT extracoronal attachment made from fiber-reinforced composite resin

Bilateral OT extracoronal attachments will be milled from fiber-reinforced composite resin after obtaining impressions of the prepared abutments. This will be followed by an overall impression of fabricating a Co-Cr removable partial denture to be retained in the attachments.

OTHER

Mandibular removable partial denture retained on OT extracoronal attachment made from porcelain-fused to metal

Bilateral OT attachments manufactured from porcelain fused to metal by conventional technique after obtaining impressions of the prepared abutments. This will be followed by an overall impression of fabricating a Co-Cr removable partial denture to be retained in the attachments.

Locations (1)

Faculty of Dentistry Ain Shams University

Cairo, Egypt