Tundra Space

Tundra Space

Clinical Research Directory

Browse clinical research sites, groups, and studies.

Back to Studies
RECRUITING
NCT06908824
NA

No Endotamponade for Macular Hole Repair: the NEMAR Study

Sponsor: Chinese University of Hong Kong

View on ClinicalTrials.gov

Summary

Full-thickness macular hole (MH) is a common sight threatening macular condition with a prevalence of 3.3 per 1000 individuals. Prompt surgical repair of MH is imperative in preventing irreversible vision loss from MH as the majority of patients would experience progressive loss of central vision, often resulting in visual acuity (VA) of 20/200 or worse and the spontaneous closure rate is less than 10%. Pars plana vitrectomy (PPV) with internal limiting membrane (ILM) peeling (with or without ILM flap) and gas tamponade, herein referred to as conventional surgery, is the current standard-of-care surgical technique in repairing MH. Recently, a novel surgical technique that omits the need of gas tamponade to repair MH has been proposed, early results from retrospective studies were encouraging. The purpose of this prospective international multi-centre randomised controlled study is to compare the efficacy and safety of two surgical techniques in treating MH: 1. Conventional surgery: PPV with ILM peeling and gas or silicone oil tamponade 2. ILM flap with no gas tamponade surgery: PPV with ILM flap with no gas tamponade

Official title: The No Endotamponade for Macular Hole Repair (NEMAR) Study: An International Multi-center Randomized Controlled Trial Comparing Macular Hole Closure Using Internal Limiting Membrane Flap Without Endotamponade Versus Conventional Surgery

Key Details

Gender

All

Age Range

18 Years - Any

Study Type

INTERVENTIONAL

Enrollment

180

Start Date

2025-09-16

Completion Date

2027-12-31

Last Updated

2025-09-30

Healthy Volunteers

No

Interventions

PROCEDURE

Conventional surgery

Pars plana vitrectomy (PPV) with temporal internal limiting membrane (ILM) flap would be performed. Perfluorocarbon liquid (PFCL) or viscoelastic may be used as an adjunct. Air/Fluid exchange would be performed at the end of surgery, further exchange of air with 8-14% octafluoropropane (C3F8) would be performed based on operating surgeon's discretion. In cases a temporal ILM flap could not be created, an ILM flap would be created from other quadrants, for example, a nasal ILM would be created instead. Patients with visually significant cataract may undergo concomitant phacoemulsification and intraocular lens implantation or deferred to post-operative month 6-12. Patients would be instructed to adopt a face-down posturing in the first 5 days following operation.

PROCEDURE

ILM flap with no gas tamponade

Pars plana vitrectomy with temporal internal limiting membrane (ILM) flap would be performed. The ILM flap would be stabilised over the macular hole using perfluorocarbon liquid (PFCL) followed by sub-PFCL dispersive viscoelastic injection. The PFCL would be removed towards the end of surgery. In cases a temporal ILM flap could not be created, an ILM flap would be created from other quadrants, for example, a nasal ILM would be created instead. Concomitant phacoemulsification and intraocular lens implantation would be performed in patients with visually significant cataract or deferred to post-operative month 6-12. Patients will be instructed to avoid excessive movement and adopt a face forward/ supine position for first 24 hours. Afterwards, there would be no restriction on post-operative posturing.

Locations (3)

Hong Kong Eye Hospital

Hong Kong, Hong Kong

Poznan University of Medical Sicences, University Hospital in Poznan

Poznan, Poland

Chang Gung Memorial Hospital

Taoyuan District, Taiwan