Tundra Space

Tundra Space

Clinical Research Directory

Browse clinical research sites, groups, and studies.

Back to Studies
ENROLLING BY INVITATION
NCT06918275
NA

Laparoscopic Isthmocele Repair

Sponsor: Kanuni Sultan Suleyman Training and Research Hospital

View on ClinicalTrials.gov

Summary

To evaluate postoperative outcomes in patients with isthmocele undergoing laparoscopic repair, comparing the efficacy of V-LocTM 180 and Polyglactin 910 Vicryl sutures. Patients were randomized to undergo laparoscopic isthmocele repair using one of the following suture materials: (1) V-LocTM 180 or (2) Polyglactin 910 Vicryl.

Official title: Efficacy and Safety of V-LocTM 180 Barbed Sutures Compared to Polyglactin 910 Vicryl in Laparoscopic Isthmocele Repair: A Prospective Randomized Study

Key Details

Gender

FEMALE

Age Range

18 Years - 45 Years

Study Type

INTERVENTIONAL

Enrollment

40

Start Date

2025-05-30

Completion Date

2026-03-15

Last Updated

2025-07-17

Healthy Volunteers

No

Conditions

Interventions

PROCEDURE

Laparoscopic isthmocele repair using V-LocTM 180 barbed suture

The standardized surgical steps for the laparoscopic isthmocele repair were as follows; 1) A 30-degree telescope was introduced through a 10 mm trocar at the umbilicus following the establishment of pneumoperitoneum. 2) Three 5 mm trocars were inserted: two in the bilateral lower quadrants and one in the suprapubic region. 3) The bladder was distended with 300 cc of saline infusion to facilitate dissection of the vesicovaginal space and to allow inferior mobilization of the bladder, thereby ensuring optimal visualization of the isthmocele region. Dissection was performed laterally up to the level of the uterine arteries, thereby minimizing the risk of vascular injury. 4) The light source of the laparoscope was deactivated, enabling the identification of the isthmocele region by utilizing the illumination provided by the hysteroscope. 5) Excision of the abnormal tissue was carried out using an ultrasonic energy device (HARMONIC®), guided by the manipulator shaft as a landmark.

OTHER

Laparoscopic isthmocele repair using Polyglactin 910 vicryl suture

The standardized surgical steps for the laparoscopic isthmocele repair were as follows; 1) A 30-degree telescope was introduced through a 10 mm trocar at the umbilicus following the establishment of pneumoperitoneum. 2) Three 5 mm trocars were inserted: two in the bilateral lower quadrants and one in the suprapubic region. 3) The bladder was distended with 300 cc of saline infusion to facilitate dissection of the vesicovaginal space and to allow inferior mobilization of the bladder, thereby ensuring optimal visualization of the isthmocele region. Dissection was performed laterally up to the level of the uterine arteries, thereby minimizing the risk of vascular injury. 4) The light source of the laparoscope was deactivated, enabling the identification of the isthmocele region by utilizing the illumination provided by the hysteroscope. 5) Excision of the abnormal tissue was carried out using an ultrasonic energy device (HARMONIC®), guided by the manipulator shaft as a landmark.

Locations (1)

Basaksehir Cam and Sakura City Hospital

Istanbul, Istanbul, Turkey (Türkiye)