Tundra Space

Tundra Space

Clinical Research Directory

Browse clinical research sites, groups, and studies.

Back to Studies
SUSPENDED
NCT06934928
NA

Assessing the Efficacy of Repeat, Monthly Treatments of Alexandrite Laser for NF1-associated Cutaneous Neurofibromas (cNFs)

Sponsor: Massachusetts General Hospital

View on ClinicalTrials.gov

Summary

The goal of this clinical trial is to evaluate the tolerability and effectiveness of multiple treatments of Alexandrite (755 nm) Laser in those with Neurofibromatosis Type 1 (NF1) Cutaneous Neurofibromas (cNFs). The main questions it aims to answer are: Will performing up to 6 months of treatment sessions with alexandrite laser will result in tolerable local skin reactions and reduction in both individual cNF size by \>50% as well as improved cNF appearance in the treated field? If there is a comparison group: Researchers will compare laser treatment with cooling to both laser treatment without cooling and an untreated control see if laser treatments are effective and if cooling makes treatment more tolerable. Participants will: * Receive up to 6 monthly laser treatments. * Complete surveys asking about pain during and after treatments. * Complete surveys asking about satisfaction with the treatments. * Undergo 2D photography and 3D imaging of treatment areas. * Optionally, receive biopsies of up to 6 treated lesions to investigate characteristics of tumors that respond well to treatment as well as non-respondent tumors.

Official title: Assessing the Efficacy of Repeat, Monthly Treatments of Alexandrite Laser for NF1 Associated Cutaneous Neurofibromas (cNFs)

Key Details

Gender

All

Age Range

18 Years - Any

Study Type

INTERVENTIONAL

Enrollment

10

Start Date

2027-01

Completion Date

2027-12

Last Updated

2026-06-04

Healthy Volunteers

No

Interventions

DEVICE

GentleMax Pro (with skin cooling)

Treatment will be performed with the GentleMax Pro laser (755 nm wavelength), which targets hemoglobin. A negative pressure hand piece provides temporary, mild suction (\~1/2 atm) before laser exposure. A pulse fluence of 60-100 J/cm2 (single or double pulse) will be used with 8 mm diameter exposure spot size, and 3 ms pulse duration. The laser system includes a dynamic cryogen spray cooling device (DCD) for epidermal protection. A spurt of cryogen cools the epidermis just before arrival of the treatment laser pulse.

DEVICE

GentleMax Pro (without skin cooling)

Treatment will be performed with the GentleMax Pro laser (755 nm wavelength), which targets hemoglobin. A negative pressure hand piece provides temporary, mild suction (\~1/2 atm) before laser exposure. A pulse fluence of 60-100 J/cm2 (single or double pulse) will be used with 8 mm diameter exposure spot size, and 3 ms pulse duration.

Locations (1)

Wellman Center for Photomedicine, Massachusetts General Hospital

Boston, Massachusetts, United States