Clinical Research Directory
Browse clinical research sites, groups, and studies.
Fine-needle Biopsy Combined With Macroscopic On-site Evaluation for Diagnosis of Solid Pancreatic Lesions
Sponsor: Changhai Hospital
Summary
The goal of this clinical trial is to compare the diagnostic efficacy, core tissue acquisition ability, number of punctures and puncture time of macroscopic on-site evaluation (MOSE) and two punctures alone in Endoscopic ultrasound guided fine-needle biopsy (EUS-FNB) for solid pancreatic lesions. The main questions it aims to answer is: whether the diagnostic accuracy of EUS-FNB performed with two needle passes is not inferior to that of MOSE. Participants with solid pancreatic lesions who needs histological diagnosis will receive EUS-FNB using 22G Franseen. In Group 1, the macroscopically visible core (MVC) of the specimen was assessed. If the MVC of the sample obtained from the first needle was ≥10mm, the tissue strip was placed in Bottle A and fixed with formalin. A second needle was then used to obtain another tissue strip, which was directly placed into Bottle B containing formalin. However, if the MVC of the first needle sample was \< 10mm, the puncture procedure was continued until the cumulative length of sample's MVC was ≥10mm, and all the sample collected during this process were placed into Bottle A and fixed with formalin. In Group 2, two needles were used to obtain tissue strips, and all the tissue strips were placed into Bottle A formalin. Researchers will compare the diagnostic efficacy, core tissue acquisition ability, number of punctures and puncture time between the MOSE technique and two-needle puncture method.
Official title: Endoscopic Ultrasound-guided Fine-needle Biopsy With or Without Macroscopic On-site Evaluation for Diagnosis of Solid Pancreatic Lesions: A Prospective Multicenter Randomized Controlled Non-Inferiority Trial
Key Details
Gender
All
Age Range
18 Years - 80 Years
Study Type
INTERVENTIONAL
Enrollment
148
Start Date
2025-06-25
Completion Date
2026-08-26
Last Updated
2025-06-06
Healthy Volunteers
No
Conditions
Interventions
MOSE application
The length of the tissue strips was judged using the specimen table and photographed for record. If the MVC of the first needle sample was ≥10mm, the tissue strip was placed into bottle A formalin for fixation. A second needle of tissue strip was pushed directly into the B-bottle formalin. If the first needle sample MVC was \< 10mm, the puncture was continued until the total length of sample MVC was ≥10mm, and all samples were placed into bottle A formalin.
Conventional processing
Two needles were punctured and all tissue strips were placed into bottle A formalin.
Locations (1)
Changhai Hospital
Shanghai, Shanghai Municipality, China