Tundra Space

Tundra Space

Clinical Research Directory

Browse clinical research sites, groups, and studies.

Back to Studies
NOT YET RECRUITING
NCT07012460
NA

Pulsed Field Ablation for Cavotricuspid Isthmus Dependent Atrial Flutter Cohort Study

Sponsor: Chinese University of Hong Kong

View on ClinicalTrials.gov

Summary

Pulsed field ablation (PFA) has been demonstrated to be safe and effective in achieving pulmonary vein isolation in patients with atrial fibrillation (AF). Coexisting atrial flutter is common in patients with AF. It is therefore appealing to treat the atrial futters with PFA. The use of PFA for extra-pulmonary ablation, such as linear ablation at the mitral or cavo-tricuspid isthmus (CTI) has been investigated. When PFA is applied near a coronary vessel, acute coronary spasm is a common observation, which has been reported to be reversible and largely mitigated by pre-emptive intravenous or intracoronary nitroglycerine (TNG) injection. A recent clinical study based on qualitative coronary angiogram reported no apparent coronary stenosis 6 months after PFA. However, quantitative measurements were not provided. While acute conduction block is easy to create with pulsed field ablation catheters, the long-term lesion durability is unknown. The circular array pulsed field ablation catheter was shown to be safe and effective in achieving pulmonary vein isolation. This study aims to evaluate the safety and efficacy of pulsed-field ablation for CTI flutters. This study will be a multicenter prospective cohort study involving 30 patients undergoing ablation for atrial fibrillation and CTI flutter. The decision for ablation will be a clinical decision based on existing class I and II guideline recommendations. The atrial fibrillation ablation procedure will be performed as per routine clinical practice. Procedure will be performed with a 3-D electro-anatomical system guidance. Pulmonary vein isolation (PVI) will be performed with pulsed field ablation with a circular array catheter (Pulse Select system, Medtronic). After confirming PVI, extrapulmonary ablation will be performed per clinically need. CTI ablation will be performed with PFA as planned. Patient will be managed by usual clinical care after ablation. They will come back for follow up at 3 months for a remapping procedure. During the remapping procedure, a RCA coronary angiogram will be performed to exclude late coronary damage. A multipolar catheter will be inserted via right femoral vein to check for conduction block across CTI. If there is ongoing conduction, a repeat ablation will be performed with radiofrequency ablation.

Key Details

Gender

All

Age Range

18 Years - 80 Years

Study Type

INTERVENTIONAL

Enrollment

30

Start Date

2025-06

Completion Date

2026-06

Last Updated

2025-06-10

Healthy Volunteers

No

Interventions

DEVICE

CTI ablation

CTI ablation will be performed with PFA. Before ablation, The RA geometry will be created with a multipolar catheter. Coronary angiogram will be performed at baseline in LAO 45 degree before and after each set of ablations. After ablation, a 15-minute waiting period will be mandated. The CTI block will be rechecked with 3D mapping system and multipolar catheter. If there is persistent CTI conduction, ablation will be repeated until CTI block is achieved. This will be followed by another 15 minutes of waiting period before rechecking the block across CTI, and so on. TNG will be prepared. It will be given via intracoronary route in 100-200mcg bolus if severe spasm is observed. If CTI block cannot be achieved with repeated PFA ablation, ablation with radiofrequency will be allowed to achieve block. Patient will come back for follow up at 3 months for a remapping procedure. During the remapping procedure, a RCA coronary angiogram will be performed to exclude late coronary damage.

Locations (1)

Prince of Wales Hospital

Hong Kong, Hong Kong