Clinical Research Directory
Browse clinical research sites, groups, and studies.
Intestinal Hyperechogenicity Confirmed by Evaluation of Gray Spectra
Sponsor: Hospices Civils de Lyon
Summary
Hyperechoic bowel is an ultrasound anomaly observed in screening and diagnostic ultrasound, and associated with various fetal pathologies including cystic fibrosis, chromosomal abnormalities, maternal-fetal infections (notably Cytomegalovirus CMV) and intrauterine growth retardation. Suspicion of hyperechogenic intestines in a fetus during a screening ultrasound leads to referral of the mother to a specialized antenatal diagnostic consultation. If the diagnosis is confirmed, this may lead to further investigations, including genetic analyses, which are costly for the healthcare system. However, many of the patients referred after a screening examination for this reason actually have their diagnosis invalidated during the specialized consultation. These "false alarms" lead to an overload of specialist consultations, and are a source of concern for couples. . However, many of the patients referred after a screening examination for this reason actually have their diagnosis invalidated during the specialist consultation. These "false alarms" lead to an overload of specialist consultations, and are a source of concern for couples. The diagnosis of intestinal hyperechogenicity is difficult because it is based on the sonographer's subjective impression, with a 3-grade gradation according to the echogenicity of the intestine in relation to the bone (Slotnick and Abuhamad. 1996). According to this method, the evaluation is carried out by progressively decreasing the gain applied to the image: if the hyperechoic bowel disappears before the iliac bone, it's a grade 1; if the bowel and iliac bone disappear at the same time, it's a grade 2; and finally if the bowel is still visible on the image while the iliac bone has disappeared, it's a grade 3. In addition to gain, which, if too high, tends to overestimate the diagnosis of hyperechoic bowel, other ultrasound parameters can vary the subjective impression of bowel echogenicity, such as the use of high-frequency probes or the application of harmonics, which also lead to overdiagnosis (Lee and Cho. 2003).
Key Details
Gender
FEMALE
Age Range
18 Years - Any
Study Type
OBSERVATIONAL
Enrollment
50
Start Date
2025-10-01
Completion Date
2026-01-01
Last Updated
2025-09-18
Healthy Volunteers
No
Conditions
Interventions
Evaluation of echogenicity
Patients ongoing a routine 2nd or 3rd trimester ultrasound will have an extra 5 minutes of ultrasound with a specific intestinal setting
Locations (1)
Hôpital Edouard Herriot
Lyon, Rhone, France