Tundra Space

Tundra Space

Clinical Research Directory

Browse clinical research sites, groups, and studies.

Back to Studies
NOT YET RECRUITING
NCT07041957
NA

Biphasic Positive Airway Pressure Ventilation Versus Flow-Controlled Ventilation in Burn Patients

Sponsor: University Hospital Bergmannsheil Bochum

View on ClinicalTrials.gov

Summary

The goal of this clinical trial is to learn if the new ventilation mode flow-controlled ventilation (FCV) is a more protective mode of ventilation for adult patients after severe burn injury. The main question it aims to answer is: Does FCV reduce the mechanical power (a key determinant of ventilator-induced lung injury) compared to conventional pressure-controlled ventilation (PCV) during ventilation of patients with burn injury? Researchers will compare FCV with PCV for up to 70 hours of ventilation to see if the mechanical power is reduced during ventilation of participants being in need of ventilation after severe burn injury. Ventilation of participants will be controlled by either FCV or PCV. Group-specific ventilation will have the following characteristics: * FCV: Control of airway flows during inspiration and expiration, use of individualized lower and upper airway pressures and no fixed values for the volumes being inspired and expired (tidal volumes) * PCV: No control of airway flows during expiration, use of individualized lower airway pressures and upper airway pressures for a fixed tidal volume during each breath (6-8 ml/kg ideal body weight) In total, at least 24 participants in need of ventilation after severe burn injury will be ventilated either with FCV (12 participants) or PCV (12 participants) for up to 70 hours. During ventilation mechanical power is computed according to certain ventilation parameters. Additionally, we evaluate organ functions of the cardiovascular systems, the lungs and other organs during and after the group-specific ventilation.

Official title: Biphasic Positive Airway Pressure Ventilation Versus Flow-Controlled Ventilation in Burn Patients: A Monocentric, Randomized Controlled, Parallel Group Trial

Key Details

Gender

All

Age Range

18 Years - 80 Years

Study Type

INTERVENTIONAL

Enrollment

24

Start Date

2025-07

Completion Date

2028-06

Last Updated

2025-06-27

Healthy Volunteers

No

Interventions

OTHER

Individualized flow-controlled ventilation strategy

1. Compliance-guided PEEP trial: An incremental PEEP trial from 5 to 15 cmH2O in 2 cmH2O steps with a constant driving pressure (ΔP) will be performed. At the first PEEP level, the tidal volume is set to 6-8 ml/kg PBW. The best PEEP level is defined as the one with the highest dynamic compliance. Participants are ventilated with this PEEP level + 1-2 cmH2O for a reduction of lung de-recruitment and atelectrauma. 2. Compliance-guided driving pressure (ΔP) trial: In the FCV group, an additional incremental ΔP trial in 1 cmH2O steps is initiated after the PEEP trial. This trial evaluates if the tidal volume increases (over-)proportional to the dynamic compliance on the previous ΔP level when the ΔP is increased by 1 cmH2O. In the FCV group, participants are ventilated with a ΔP consistent with the highest dynamic compliance ± 1-2 cmH2O. The compliance-guided PEEP and ΔP trials are repeated every 8 hours in order to account for changes in overall lung compliance.

OTHER

Pressure-controlled ventilation strategy via the application of Biphasic Positive Airway Pressure ventilation

1. Compliance-guided PEEP trial: An incremental PEEP trial from 5 to 15 cmH2O in 2 cmH2O steps with a constant driving pressure (ΔP)will be performed. At the first PEEP level, the tidal volume is set to 6-8 ml/kg PBW. The best PEEP level is defined as the one with the highest dynamic compliance. Participants are ventilated with this PEEP level + 1-2 cmH2O for a reduction of lung de-recruitment and atelectrauma. 2. The driving pressure (ΔP) is set to achieve a tidal volume of 6-8 ml/kg predicted body weight. The compliance-guided PEEP trial is repeated every 8 hours in order to account for changes in overall lung compliance.

Locations (1)

BG University Hospital Bergmannsheil, Ruhr University Bochum

Bochum, Germany