Tundra Space

Tundra Space

Clinical Research Directory

Browse clinical research sites, groups, and studies.

Back to Studies
RECRUITING
NCT07042529
NA

Optimized Expansion of the Implanted Transcatheter Aortic Valve

Sponsor: Ole De Backer

View on ClinicalTrials.gov

Summary

Optimized Expansion of the implanted transcatheter aortic valve to reduce hypoattenuating leaflet thickening in non-atrial fibrillation patients undergoing transcatheter aortic valve implantation (TAVI): an international, multicentre, randomized controlled trial. The objective is to evaluate whether TAVI with systematic optimized pre- and post-dilatation (optimized expansion (OptEx) TAVI strategy), compared to a standard of care (SoC) TAVI strategy, is superior in reducing hypoattenuating leaflet thickening as evaluated by cardiac computed tomography (CT) imaging at three months after TAVI. The primary outcome is at least one thickened TAV leaflet involving ≥ 25% of the leaflet curvilinear dimension as assessed at cardiac CT at three months after TAVI.

Official title: Optimized Expansion of the Implanted Transcatheter Aortic Valve to Reduce Hypoattenuating Leaflet Thickening in Non-atrial Fibrillation Patients Undergoing Transcatheter Aortic Valve Implantation: an International, Multicentre, Randomized Controlled Trial

Key Details

Gender

All

Age Range

18 Years - Any

Study Type

INTERVENTIONAL

Enrollment

620

Start Date

2025-10-05

Completion Date

2033-07-01

Last Updated

2026-02-03

Healthy Volunteers

No

Interventions

PROCEDURE

OptEx-TAVI

During TAVI with either self-expanding or balloon-expandable TAVs: * Pre-dilatation: systematic pre-dilatation with an optimally-sized balloon. * Post-dilatation: systematic TAV post-dilatation with an optimally-sized balloon. Optimally-sized balloon: 1. The recommended balloon size used for pre- and post-dilatation is the perimeter-derived mean diameter of the native aortic annulus minus 1 mm and should never exceed the perimeter-derived mean diameter of the native aortic annulus. A smaller-sized balloon should be considered in case of severe left ventricular outflow tract calcium and/or severely calcified leaflets in combination with a shallow sinus of Valsalva. 2. In case of post-dilatation of the Evolut TAV (Medtronic, USA), the instructions for use (IFU) for post-dilatation of the Evolut valve should be respected. 3. Also, a balloon-expandable TAV has to be post-dilated with an optimally-sized balloon in case of randomization to the OptEx-TAVI arm.

PROCEDURE

SoC-TAVI

During TAVI with either self-expanding or balloon-expandable TAVs: Pre-dilatation: optional, as per operator preference and post-dilatation: optional, as per operator preference. Operators are only encouraged to post-dilate the implanted TAV in case of ≥ moderate paravalvular regurgitation or a suboptimal transvalvular gradient. The balloon size used for pre- or post-dilatation is left at the operator's discretion.

Locations (10)

CHU Charleroi

Charleroi, Belgium

UZ Leuven

Leuven, Belgium

Skejby Hospital

Aa, Denmark

Aalborg University Hospital

Aalborg, Denmark

Rigshospitalet

Copenhagen, Denmark

Odense University Hospital

Odense C, Denmark

Turku University Hospital

Turku, Finland

St. Antonius Hospital

Nieuwegein, Netherlands

Oslo universitetssygehus

Oslo, Norway

Sahlgrenska University Hospital

Gothenburg, Sweden