Tundra Space

Tundra Space

Clinical Research Directory

Browse clinical research sites, groups, and studies.

Back to Studies
NOT YET RECRUITING
NCT07137806
NA

Enhanced Pain Relief With Ultrasound Guided Combined Submaltifidus and Sacroiliac Joint Injection

Sponsor: Tanta University

View on ClinicalTrials.gov

Summary

Sacroiliitis is not the same as SI joint dysfunction. Sacroiliitis is specific to an inflammatory processes present in the SI joint and the pain sensed is a direct result of those inflammatory processes, whereas sacroiliac joint dysfunction is a condition caused by abnormal motion or slight mispositioning of the SI joint. Sacroiliac joint syndrome is a condition that is difficult to diagnose and is often overlooked by physicians and physiotherapist

Official title: Beyond the Joint: Enhanced Pain Relief With Ultrasound Guided Combined Submaltifidus and Sacroiliac Joint Injection - a Randomized Controlled Trial

Key Details

Gender

All

Age Range

21 Years - Any

Study Type

INTERVENTIONAL

Enrollment

62

Start Date

2025-08-20

Completion Date

2026-03-30

Last Updated

2025-08-22

Healthy Volunteers

No

Conditions

Interventions

PROCEDURE

sacroiliac joint injection

Ultrasound-guided injection of the SI joints The patient is placed in a prone position to receive this injection treatment. The Curvilinear transducer is placed in a transverse orientation to identify the sacral hiatus first. After identifying the sacral cornu, the transducer is moved in a lateral direction until the lateral edge of the sacrum is observed. With the transducer maintained in the transverse orientation, it is then moved in a cephalad or upward direction until the bony contour of the ileum is identified. The cleft between the bony contours of the sacrum and ileum represents the posterior aspect of the SI joint. By tilting the transducer in a caudal direction, the lower one third of the SI joint is identified. Because of its synovial component, the lower one third of the SI joint is the portion of the entire SI joint in which the injection should be performed. The medial to lateral approach and intraarticular deposition is preferred for the ultrasound-guided SI joint

PROCEDURE

combined sacroiliac joint injection and sub maltifidous plane block

patients will be positioned prone. A 6-13 MHz linear array ultrasound transducer was placed in the parasagittal orientation with the second sacral foramen (SF-2) in the field. A 21G short bevel needle is inserted in-plane approach from the cephalad to the caudad direction. After hitting the underlying bone, twenty millilitres of local anaesthetic solution (1:1 mixture of lidocaine 2% and bupivacaine 0.25%) will be injected. An anechoic LA spread in the plane between the multifidus muscle (MFM) and the hyperechoic bony area (between the median and intermediate sacral crests) will be confirmed. The Curvilinear transducer is placed in a transverse orientation to identify the sacral hiatus first. After identifying the sacral cornu, the transducer is moved in a lateral direction until the lateral edge of the sacrum is observed. With the transducer maintained in the transverse orientation, it is then moved in a cephalad or upward direction until the bony contour of the ileum is identified.

Locations (1)

Tanta University

Tanta, Egypt