Clinical Research Directory
Browse clinical research sites, groups, and studies.
Efficacy and Safety of Task-specific, Biomarker-driven, HD-ctACS inTRD.
Sponsor: Ruijin Hospital
Summary
This is a single-center, randomized, double-blind, sham-controlled, crossover exploratory clinical trial designed to evaluate the therapeutic effects of task-specific, biomarker-driven HD-ctACS on treatment-resistant depression (TRD). The study will enroll 10 patients diagnosed with TRD. Each participant will, in a randomized order, undergo a 4-week active HD-ctACS treatment period and a 4-week sham stimulation (delayed HD-ctACS) period, separated by an 8-week washout period. The primary objective is to assess the efficacy of HD-ctACS in improving core depressive symptoms, with the primary outcome being the difference in the Hamilton Depression Rating Scale (HAMD) total score between the end of the two intervention periods. Secondary objectives include evaluating the safety of the therapy, its effects on other symptom dimensions, and exploring its modulatory effects on neurobiological markers of emotional processing (e.g., NAc gamma power). The total participation time for each subject is approximately 16 weeks.
Official title: Efficacy and Safety of Task-specific, Biomarker-driven, High-definition, Closed-loop Transcranial Alternating Current Stimulation (HD-ctACS) in Treatment-Resistant Depression (TRD): A Randomized, Double-blind, Sham-controlled, Crossover Trial.
Key Details
Gender
All
Age Range
18 Years - 65 Years
Study Type
INTERVENTIONAL
Enrollment
10
Start Date
2025-08-14
Completion Date
2026-01-01
Last Updated
2025-09-22
Healthy Volunteers
No
Conditions
Interventions
HD ctACS
Participants received High-Definition closed-loop transcranial Alternating Current Stimulation (HD-ctACS) for 30 minutes daily, 5 days per week. A 4x1 ring electrode montage was used, with the center electrode placed over the bilateral temporal cortices. Stimulation was delivered as a sinusoidal alternating current at a 2 mA peak amplitude, with the frequency individualized for each participant based on their baseline EEG. The stimulation was administered in a closed-loop, task-specific manner: a 500 ms burst of stimulation was triggered only when a subliminal negative facial stimulus was presented and the participant's real-time Nucleus Accumbens gamma power exceeded their baseline by two standard deviations.
HD ctACS sham
Participants received High-Definition transcranial Alternating Current Stimulation (HD-tACS) in 30-minute sessions once daily, 5 days per week. A 4x1 ring electrode layout was used to target the bilateral temporal cortices. The stimulation consisted of a sinusoidal alternating current with a 2 mA peak intensity, delivered at an individualized gamma frequency determined from a baseline EEG. The intervention was administered using a closed-loop, task-specific paradigm: upon presentation of a subliminal negative facial stimulus while the real-time Nucleus Accumbens gamma power exceeded a baseline threshold of +2 SD, a 500 ms stimulation was delivered following a random delay of 1000-2000 ms.
Locations (1)
Ruijin Hospital
Shanghai, Shanghai Municipality, China