Summary
Ischaemic strokes, caused by a disruption in the brain's blood supply, are the second leading cause of death and disability in the United Kingdom. This single-center prospective randomised study aims to measure cerebral blood flow and oxygen delivery in patients who have recently suffered an ischaemic stroke and are using either the geko® neuromuscular electrostimulation device or an intermittent pneumatic compression (IPC) device as part of their routine clinical care. The geko® device stimulates a nerve in the lower leg, inducing muscle contractions that enhance blood circulation. The IPC device applies controlled external pressure through compressed air and a pump, cyclically inflating and deflating chambers in a sleeve worn on the leg. This mimics the action of calf muscles to promote blood flow. The primary objective of this study is to assess the effect of the geko® and IPC devices on cerebral blood flow in stroke patients, specifically during the hyperacute phase (within 36 hours) following an ischaemic stroke. Both devices will be used as part of standard care for VTE prevention. Cerebral blood flow will be measured using functional near-infrared spectroscopy (fNIRS) and electroencephalography (EEG).
Official title: MonitoRing the Effect of Intermittent Pneumatic Compression and TRAnscutaneous Functional electrIcal Stimulation of the Common Peroneal Nerve Using the Geko® Device on Cerebral Haemodynamics in Patients With Ischaemic Strokes (The RETRAIN Trial Phase 2)
Key Details
Gender
All
Age Range
18 Years - Any
Study Type
INTERVENTIONAL
Enrollment
80
Start Date
2025-07-01
Completion Date
2026-07-01
Last Updated
2025-09-30
Healthy Volunteers
No
Conditions
Interventions
Intermittent Pneumatic Compression
The IPC arm will use the Kendall SCD™ 700 Sequential Compression System, a routinely employed device for VTE prophylaxis in stroke patients. In this study, IPC sleeves will be applied bilaterally to the legs within 36 hours of stroke onset and operated according to the manufacturer's instructions. The intervention is distinguished by its cyclical external leg compression to enhance venous return, and it serves as the comparator to the geko® device for evaluating effects on cerebral blood flow and haemodynamics.
geko® T3
The geko® T3 device is a small, disposable, battery-powered neuromuscular electrostimulation device manufactured by Firstkind Ltd. In this study, the geko® will be applied bilaterally to the common peroneal nerve at the knee within 36 hours of stroke onset. It delivers transcutaneous electrical stimulation at 1 Hz, producing involuntary rhythmic foot dorsiflexion to activate the calf and foot muscle pumps. The intervention is distinguished from IPC by its mechanism of action (neuromuscular stimulation vs. external compression) and will be evaluated for its impact on cerebral haemodynamics, neurovascular coupling, and dynamic cerebral autoregulation during VTE prophylaxis.