Effect of HFNC on Incidence of Hypoxia During Sedated Gastrointestinal Endoscopy in Critical Patients

Sponsor: Zhejiang University

View on ClinicalTrials.gov

Summary

High flow nasal cannula oxygenation (HFNC) offers high flow and concentration oxygen delivery, providing excellent non-respiratory oxygenation. As a relatively new oxygen delivery method, it has gained widespread use. We have demonstrated that high flow nasal cannula oxygenation reduce the incidence of hypoxia during sedated gastrointestinal endoscopy in patients with American Anesthesiologist Rating (ASA rating) grades 1 to 2 and obesity. We hypothesized that HFNC could mitigate the risk of hypoxia in critical patients during sedated gastrointestinal endoscopy. To confirm this, we selected critical patients with ASA grades 3 to 4 who were scheduled for gastrointestinal endoscopy. We observed and compared the incidence of hypoxia (75%≤SpO2 \< 90% and \< 60S), severe hypoxia (SpO2\<75% for any duration or 75%≤SpO2 \< 90%, ≥60s), subclinical respiratory depression (90%≤SpO2 \< 95%), respiratory-related adverse events, sedation-related adverse events, and complications associated with high flow nasal cannula oxygenation using HFNC or regular nasal cannula during the sedated gastrointestinal endoscopy.

Official title: Effect of High Flow Nasal Cannula Oxygenation on Incidence of Hypoxia During Sedated Gastrointestinal Endoscopy in Critical Patients: A Multicentre Randomised Controlled Trial

Key Details

Gender

All

Age Range

18 Years - 80 Years

Study Type

INTERVENTIONAL

Enrollment

450

Start Date

2025-11-20

Completion Date

2026-12-30

Last Updated

2026-01-20

Healthy Volunteers

No

Interventions

DEVICE

High-flow nasal catheter oxygen

Before induction of anesthesia, connect the Airvo2 (HFNC high flow device) special nasal cannula to inhale oxygen, and preoxygenate with an oxygen flow rate of 6L /min. After induction of anesthesia, adjust the oxygen flow rate to 60L /min, oxygen concentration 100%, oxygen temperature 37℃ until the end of gastrointestinal endoscopy.

DEVICE

regular nasal catheter oxygen

Before anesthesia induction, a disposable nasal catheter oxygen inhalation device (covered by HFNC nasal catheter and blinded to the patient) was connected to an oxygen source for pre-oxygen inhalation, 6L/min. After induction of anesthesia, oxygen was continued for 6L/min until the end of gastroenteroscopy.