Clinical Research Directory
Browse clinical research sites, groups, and studies.
Atrial Fibrillation Detection Using MEMO Patch in Patients With Stroke of Unknown Cause
Sponsor: Asan Medical Center
Summary
The purpose of this study is to evaluate the efficacy and safety of a wearable device in detecting previously undiagnosed atrial fibrillation through non-invasive long-term monitoring using a wearable single-lead ECG patch (MEMO Patch M, MEMO Patch2) in 100 patients with Embolic Stroke of Undetermined Source (ESUS) who require atrial fibrillation screening. Participants who meet all inclusion and exclusion criteria and provide written informed consent will wear the MEMO Patch M and undergo in-hospital telemetry monitoring using MEMO Cue for a minimum of 12 hours and up to 8 days. During hospitalization, 24-hour Holter monitoring will also be conducted. Before discharge, the investigator will review these results to determine whether implantable loop recorder (ILR) implantation is necessary. At the time of discharge, participants will wear MEMO Patch2 for up to 14 days for the first ECG monitoring period. One month after discharge, the investigator will review the results of the first monitoring and initiate the second ECG monitoring with MEMO Patch2. Three months after discharge, the results of the second ECG monitoring will be reviewed, and participation in the clinical trial will be completed.
Official title: Atrial Fibrillation Detection Using MEMO Patch in Patients With Stroke of Unknown Cause: A Single-Center, Prospective, Exploratory Trial to Validate the Efficacy and Safety of Noninvasive Long-Term Electrocardiographic Monitoring
Key Details
Gender
All
Age Range
19 Years - Any
Study Type
INTERVENTIONAL
Enrollment
100
Start Date
2026-01-28
Completion Date
2029-02-15
Last Updated
2026-02-06
Healthy Volunteers
No
Conditions
Interventions
MEMO Patch M and MEMO Patch2
During hospitalization, participants will wear MEMO Patch M, a single-lead wearable ECG patch, for 12 hours to up to 8 days. A 24-hour Holter monitor will also be performed during hospitalization. Before discharge, investigators will review the MEMO Patch M and Holter results to assess the need for implantable loop recorder (ILR) implantation. At the time of discharge, participants will wear MEMO Patch2 for up to 14 days for the first ECG monitoring period. One month after discharge, participants will undergo the second ECG monitoring period with MEMO Patch2 for up to 14 days.
Locations (1)
Asan Medical Center
Seoul, Songpa-gu, South Korea