Tundra Space

Tundra Space

Clinical Research Directory

Browse clinical research sites, groups, and studies.

Back to Studies
NOT YET RECRUITING
NCT07309666

Research, Development, and Application of Intelligent Diagnostic System for Orthostatic Hypotension

Sponsor: Xuanwu Hospital, Beijing

View on ClinicalTrials.gov

Summary

Orthostatic hypotension (OH) has a high incidence rate of 30%-50% in the elderly and populations with neurodegenerative diseases. The resulting cerebral hypoperfusion significantly increases the risk of cerebral ischemia, falls, and cognitive decline. Traditional OH diagnosis primarily relies on intermittent cuff blood pressure measurements, leading to low detection rates and an inability to provide scientifically effective OH classification. Furthermore, existing research often overlooks cerebral hemodynamic mechanisms, particularly the assessment of dynamic cerebral autoregulation (dCA), making it difficult to study the mechanisms behind OH and its associated symptoms. To address these issues, the research team has preliminarily developed an "Intelligent Diagnostic System for Orthostatic Hypotension". This system innovatively integrates synchronous and continuous monitoring of multiple parameters, including non-invasive beat-to-beat blood pressure, transcranial Doppler (TCD) cerebral blood flow velocity, and electrocardiogram (ECG). It also enables the quantitative assessment of dynamic cerebral autoregulation function. The project will collaborate with fifteen high-level clinical centers in China to collect data from 2000 patients with orthostatic hypotension. The aim is to establish and externally validate a risk stratification model for OH. By integrating multimodal clinical and hemodynamic data, the investigators intend to construct an automated, precise intelligent system for the classification, subtyping, and risk stratification of OH. This initiative will establish a standardized diagnostic and management pathway covering early screening, precise classification, early warning, and stratified intervention. The goal is to provide key technological support for enhancing the early identification and standardized management of OH, thereby reducing its associated disability and mortality rates.

Key Details

Gender

All

Age Range

18 Years - Any

Study Type

OBSERVATIONAL

Enrollment

2000

Start Date

2026-03-01

Completion Date

2029-02-01

Last Updated

2026-01-07

Healthy Volunteers

Not specified

Interventions

OTHER

Intelligent diagnostic system for orthostatic hypotension

All participants will undergo a standardized multi-parameter monitoring protocol. After resting in the supine position for at least 10 minutes, participants will perform an active standing test. During this protocol, the following parameters are continuously and synchronously recorded using the integrated intelligent diagnostic system: non-invasive beat-to-beat blood pressure, cerebral blood flow velocity in the middle cerebral artery (assessed via transcranial Doppler, TCD), electrocardiogram (ECG), and end-tidal carbon dioxide (ETCO₂). Monitoring is conducted for a 10-minute baseline period in the supine position and continues for up to 10 minutes following standing.

Locations (1)

Xuanwu Hospital, Capital Medical University

Beijing, Beijing Municipality, China