EIT-Guided PEEP Optimization in Trauma and Postoperative ARDS

Sponsor: Nguyen Dang Thu

View on ClinicalTrials.gov

Summary

Acute respiratory distress syndrome (ARDS) remains a serious and often fatal complication in patients following severe trauma or major surgery. Mechanical ventilation is essential for supportive care in this population, but may aggravate lung injury when suboptimal ventilatory settings are applied. Positive end-expiratory pressure (PEEP) is crucial for maintaining alveolar recruitment; however, optimal PEEP selection in trauma- or postoperative-associated ARDS remains uncertain. Electrical impedance tomography (EIT) enables bedside, real-time assessment of regional ventilation and may support optimal PEEP titration by balancing alveolar overdistension and collapse. This study compares EIT-guided PEEP optimization with the conventional low FiO₂-PEEP strategy in terms of oxygenation and respiratory mechanics in patients with moderate to severe ARDS following trauma or surgery.

Official title: Electrical Impedance Tomography-Guided Positive End-Expiratory Pressure Optimization in Patients With Trauma-Related and Postoperative Acute Respiratory Distress Syndrome

Key Details

Gender

All

Age Range

18 Years - 90 Years

Study Type

INTERVENTIONAL

Enrollment

80

Start Date

2025-03-15

Completion Date

2026-12-15

Last Updated

2026-01-02

Healthy Volunteers

No

Interventions

DEVICE

EIT-giuded PEEP

Device: electrical impedance tomography system (Enlight 2100, Timpel SA, Brazil). \- Patients underwent airway suctioning and were deeply sedated (RASS ≤ -3) to abolish spontaneous breathing. PEEP titration was performed using an EIT system (Enlight 2100, Timpel SA, Brazil), with a silicone belt containing 32 surface electrodes positioned at the fourth to fifth intercostal space in accordance with the manufacturer's instructions. Pressure-controlled ventilation was applied with an inspiration pressure set at 15 cmH₂O and a set PEEP of 24 cmH₂O, with a maximum airway pressure limit of 40 cmH₂O. Ventilator settings were maintained for 30 seconds with an FiO₂ of 1.0. A decremental PEEP trial was then performed by reducing PEEP in 2 cmH₂O every 30 seconds until a PEEP of 6 cmH₂O was reached or the SpO₂ decreased to ≤ 80%. The EIT-guided optimal PEEP was defined as the PEEP level corresponding to the intersection point of the collapse and overdistension curves.

DEVICE

Control

PEEP was set and adjusted according to the lower PEEP/FiO₂ table of the ARDS Network