Left Bundle Branch Versus Minimized Ventricular Pacing in Patients With Sick Sinus Syndrome and Prolonged AV Interval

Sponsor: Asan Medical Center

View on ClinicalTrials.gov

Summary

The goal of this clinical trial is to compare two pacemaker strategies: Left Bundle Branch Area Pacing (LBBAP) and Minimized Ventricular Pacing (MVP) in patients requiring a permanent pacemaker for sick sinus syndrome and prolonged AV interval. It will also evaluate the safety and feasibility of the LBBAP method in these patients. The main questions it aims to answer is: \*Is LBBAP with physiological AV interval better than Minimized Ventricular Pacing? Researchers will compare the LBBAP group (aiming for conduction system capture with physiological AV intervals) to the MVP group (aiming to minimize ventricular pacing with prolonged AV intervals) to evaluate the optimal pacing strategy. Participants will: * Be randomly assigned to either the LBBAP group or the MVP group. * Undergo a pacemaker implantation procedure according to the specific criteria for their assigned group. * Visit the clinic for regular checkups to measure pacing function and ensure the device settings remain compliant with the study protocol.

Official title: Comparison of Left Bundle Branch Area Pacing and Minimized Ventricular Pacing in Patients With Sinus Node Dysfunction and Atrioventricular Conduction Delay: A Multicenter, Randomized Controlled Clinical Trial

Key Details

Gender

All

Age Range

18 Years - Any

Study Type

INTERVENTIONAL

Enrollment

440

Start Date

2025-05-02

Completion Date

2029-01-31

Last Updated

2026-01-02

Healthy Volunteers

No

Interventions

DEVICE

LBBAP

* All pacemaker implantation should be performed in standard manner. * A lead should be placed in the right atrial appendage or septum where acceptable sensing (P wave \>1mV) and pacing threshold (\<1V at 0.4ms width). * V lead should be placed in the right ventricular septum where conduction system pacing can be achieved with acceptable sensing and pacing threshold. The pacing morphology should be compatible with His bundle pacing, right ventricular pacing, selective and non-selective left bundle branch pacing, or left fascicular pacing. * The primary objective for the LBBAP group is the achievement of conduction system capture with LBBAP. However, based on the physician's discretion or the situations in the operating room, His bundle pacing can be accepted as alternatives to LBBAP.

DEVICE

MVP

* All pacemaker implantation should be performed in standard manner. * A lead should be placed in the right atrial appendage or septum where acceptable sensing (P wave \>1mV) and pacing threshold (\<1V at 0.4ms width). * V lead should be placed in the right ventricular apex or septum where acceptable sensing (R wave \>5mV) and pacing threshold (\<1V at 0.4ms width) * The rhythmiQTM mode should be turned on * Sensing and pacing AV intervals recommended to be \>300ms (default value or more), and should not be \<200ms to minimize the ventricular pacing.

Locations (1)

Asan Medical Center

Seoul, Songpa-gu, South Korea