Tundra Space

Tundra Space

Clinical Research Directory

Browse clinical research sites, groups, and studies.

Back to Studies
NOT YET RECRUITING
NCT07361523

Using Near-Infrared Spectroscopy Devices to Assess Myocardial and Visceral Perfusion During Complex Congenital Cardiac Surgery

Sponsor: Boston Children's Hospital

View on ClinicalTrials.gov

Summary

The use of near infrared spectroscopy (NIRS) is a technique that has recently been incorporated by several other surgical specialties to measure tissue perfusion, such as in plastic surgery to allow for earlier detection of free flap vascular compromise in the postoperative monitoring protocol, with promising outcomes. IntraOx is a handheld oximeter that uses NIRS to measure tissue oxygen saturation and that has been used as an alternative to indocyanine green (ICG) to assess bowel perfusion in colorectal anastomotic cases. IntraOx is a promising technology that is also sterile and easy to use that can be incorporated into congenital heart surgery procedures to evaluate myocardial perfusion in a time sensitive manner. This technology could also be used on the liver to assess systemic perfusion as another indicator of cardiac function, in conjunction with the intraoperative transesophageal echocardiography (TEE). This could provide more concrete data about not only myocardial perfusion, but systemic perfusion as well. This data could be critical to help surgeons make surgical decisions and may help to improve patient outcomes. This will be a prospective review of the use of the Intra.Ox device during cardiac surgery at different timepoints during the procedure to assess perfusion. This device is FDA-approved for use in adults but not approved for use in children and will be investigational in children. The primary objective of this study is to test whether the Intra.Ox (Vioptix Inc.) using near-infrared spectroscopy to measure tissue oxygen saturation can be used to evaluate myocardial and visceral perfusion at different time points during complex congenital heart surgery, and particularly those involving coronary artery manipulation such as patients undergoing arterial switch operations or stage 1 palliation for hypoplastic left heart syndrome. The investigators would also use this device on the liver to assess systemic perfusion. The secondary objective is to evaluate whether the investigators would be able to use the information from the Intra.Ox device to make clinical decisions that can improve patient outcomes.

Key Details

Gender

All

Age Range

1 Year - Any

Study Type

OBSERVATIONAL

Enrollment

50

Start Date

2026-01-01

Completion Date

2027-12-31

Last Updated

2026-01-23

Healthy Volunteers

No

Interventions

DEVICE

Tissue oximeter (IntraOx)

The Intra.Ox device will be used to measure %StO2 readings taken at different time points during the surgery, including: (1) prior to bypass when the heart is being perfused by the coronary arteries, (2) after the patient is placed on cardiopulmonary bypass (CPB) but prior to placing a cross-clamp, (3) after placing a cross-clamp when the heart is not being perfused by CPB, and (4) after the patient is taken off CPB and the heart is re-perfusing. These readings will not impact the surgical management of the patient, and the congenital heart surgery will be carried out per standard of care according to the judgement of the surgeon.