Clinical Evaluation of an AI- and Ultrasound-Assisted Venipuncture Device
Sponsor: Seoul National University Hospital
Summary
Purpose : This study aims to confirm the safety and efficacy of AIIV L2, an artificial intelligence- and ultrasound-based medical device that assists venipuncture, by comparing venipuncture performed using AIIV L2 with manual venipuncture. Study Design : This is a single-center, randomized, crossover, prospective, open-label, non-inferiority confirmatory clinical trial. Methods : Each participant will undergo venipuncture on both arms: one arm using AIIV L2 and the other arm using manual venipuncture, according to randomized allocation. After venipuncture is performed on both arms, outcomes including venipuncture success rate, procedure time, pain, and hemolysis will be evaluated. All venipuncture procedures will be performed by the same operator. Vital signs and adverse events will be monitored before and after the procedure. \- Primary Efficacy Endpoint Venipuncture success rate: Comparison of the success rate of venipuncture on the first attempt between AI-assisted venipuncture and manual venipuncture. \- Secondary Efficacy Endpoints Procedure time: Time from needle insertion to completion of venipuncture. Hemolysis rate: Presence of hemolysis in collected samples, determined according to laboratory criteria. Pain score (NRS): Numeric Rating Scale (0-10) reported by participants after each venipuncture method. Within-subject pain comparison: Comparison of pain scores between AI-assisted and manual venipuncture within the same participant. Acceptability: Participant satisfaction and preference regarding AI-assisted venipuncture, assessed using a structured questionnaire.
Official title: A Single-Center, Randomized, Crossover, Prospective, Open-Label, Non-Inferiority Confirmatory Clinical Trial to Evaluate the Safety and Efficacy of an AI- and Ultrasound-Based Medical Device That Assists Venipuncture, Compared With Manual Venipuncture
Key Details
Gender
All
Age Range
19 Years - Any
Study Type
INTERVENTIONAL
Enrollment
190
Start Date
2026-01-26
Completion Date
2026-04-30
Last Updated
2026-02-06
Healthy Volunteers
Yes
Conditions
Interventions
AIIV L2
The investigational device is AIIV L2 (product code: H2BXXA2), an AI- and ultrasound-based medical device designed to assist venipuncture. This medical device is intended for use by healthcare professionals in medical institutions to obtain ultrasound images of the antecubital area of adult subjects, utilize an artificial intelligence model to identify the location of veins, and determine the insertion site of the needle to assist with venipuncture.
Manual venipuncture
Venipuncture will be performed manually according to standard clinical practice, without use of the investigational device.
Locations (1)
Seoul National University Hospital
Seoul, Seoul, South Korea