Tundra Space

Tundra Space

Clinical Research Directory

Browse clinical research sites, groups, and studies.

Back to Studies
NOT YET RECRUITING
NCT07397871
NA

Salivary Flow, pH, and Buffering Capacity in Fixed and Clear Aligner Orthodontic Treatment

Sponsor: Riyadh Elm University

View on ClinicalTrials.gov

Summary

Study Design: A randomized controlled trial with two parallel arms and an allocation ratio of 1:1. Setting: The study will be conducted in the orthodontic department of Riyadh Elm University hospitals in Riyadh City, Saudi Arabia. Participants: Patients undergoing fixed or clear aligner orthodontic treatment referred to REU dental hospital will be randomly allocated to either the clear aligner group or the fixed orthodontic appliance group. Intervention: Prior to orthodontic treatment, all patients will receive phase I periodontal therapy and oral hygiene instructions. Fixed orthodontic appliances will be bonded using metallic brackets with a 0.022-inch slot and 0.014-inch NiTi archwires. Clear aligner patients will receive Invisalign® treatment. Outcomes and Saliva Collection: Salivary samples will be collected using the spitting method at baseline (T0) and follow-up time points according to the study protocol. Salivary flow rate, pH, and buffering capacity will be assessed as described in the proposal. Randomization and Blinding: Randomization will be performed using a random number generator with allocation concealment via opaque envelopes. The investigators involved in outcome assessment and data analysis will be blinded. Ethical Considerations: The study will be submitted to the Institutional Review Board at Riyadh Elm University and conducted in accordance with IRB policies.

Official title: Changes in Salivary Parameters in Patients Undergoing Clear Aligner Orthodontic Treatment: A Randomized Controlled Trial

Key Details

Gender

All

Age Range

18 Years - Any

Study Type

INTERVENTIONAL

Enrollment

40

Start Date

2026-03-15

Completion Date

2027-05-29

Last Updated

2026-02-09

Healthy Volunteers

No

Interventions

DEVICE

Fixed orthodontic appliances

Study subjects in control group will receive fixed orthodontic appliances with metallic brackets of 0.022-inch slot size (American Orthodontics).

DEVICE

Clear Aligner Treatment

Study subjects in Clear Aligner treatment group will receive Invisalign® (Align Technology, Inc., Tempe, AZ, USA). The Clear Aligner treatment protocol will be followed until the end of the treatment.

Locations (1)

Riyadh Elm University

Riyadh, Saudi Arabia