Clinical Research Directory
Browse clinical research sites, groups, and studies.
Adaptive Fractionation in Online Adaptive Stereotactic Radiotherapy for Abdominopelvic Lymph Node Oligometastases
Sponsor: Joost J. M. E. Nuyttens
Summary
Oligometastases, a state of cancer with up to five metastases, was traditionally treated with systemic treatments like chemotherapy. Treatment with stereotactic body radiotherapy (SBRT) showed a high local control and improved disease-free survival. The use of SBRT also allows for the deferral of systemic treatment, thereby delaying its potential side effects. SBRT enables the delivery of a high dose to the tumor while minimizing the dose to organs at risk, reducing normal tissue damage, however, toxicity remains a potential issue in the abdominopelvic region, where lymph node oligometastases are often located near highly mobile, radiosensitive organs like the bowel. Online adaptive radiotherapy is used to address this issue, adapting the treatment plan to the anatomy of the day. Unfortunately, adaptive radiotherapy results in longer treatment delivery times than conventional radiotherapy. This can potentially be countered by increasing the fraction dose and reducing the number of fractions if the patient anatomy allows it. This is convenient for the patient as it reduces the number of hospital visits, and it could also reduce the total workload for the hospital. Therefore, there is not only a benefit of a reduction in toxicity by adaptive treatment, but also in reducing the total treatment time. This study aims to investigate if the number of adaptive fractions can be reduced by 30% for patients with abdominal or pelvic lymph node oligometastases.
Key Details
Gender
All
Age Range
18 Years - Any
Study Type
INTERVENTIONAL
Enrollment
25
Start Date
2025-02-27
Completion Date
2028-01-01
Last Updated
2026-02-17
Healthy Volunteers
No
Conditions
Interventions
Online-Adaptive SBRT
The treatment will consist of online-adaptive SBRT using the ETHOS linear accelerator. The standard treatment will be 45 Gy in 5 fractions (45Gy/5Fx). If the patient anatomy allows, the number of planned fractions will be isotoxically reduced, keeping OAR and target dose goals biologically equivalent, to a minimum of 25 Gy in 1 fraction (25Gy/1Fx). For the adaptive treatment, daily HyperSight CBCT scans will be made, and the target and OAR contours will be automatically delineated and adjusted if necessary. If, during treatment, patient anatomy changes in such a way that fewer or more fractions are required than planned, changes can be made in the daily dose and number of remaining fractions. During and after treatment, a CBCT scan is made to verify the current treatment and improve future treatments.
Locations (1)
Erasmus MC
Rotterdam, South Holland, Netherlands