Tundra Space

Tundra Space

Clinical Research Directory

Browse clinical research sites, groups, and studies.

Back to Studies
ACTIVE NOT RECRUITING
NCT07449598
NA

Evaluation of Physical Changes in Single-Layer and Multi-Layer Clear Aligners

Sponsor: Mansoura University

View on ClinicalTrials.gov

Summary

aim of the study: to evaluate and compare the surface roughness (Ra, Rq, Rz), Vickers microhardness (VHN), and thickness of single-layer and multi-layer clear aligner sheets. material and methods: the study will be conducted on clear aligners fabricated from two commercial thermoplastic materials: single-layer (0.76 mm, ) and multi-layer (0.76 mm, ). Each material will be evaluated at three stages: before thermoforming, after thermoforming on 3D-printed casts, and after 2 weeks of intraoral wear. Specimen Preparation For each group, specimens will be prepared at three stages: before thermoforming (T0), after thermoforming (T1), and after intraoral wear (T2). At T0, square-shaped specimens (approximately 5 × 5 mm) will be cut directly from the unused raw sheets. At T1 and T2, specimens of the same dimensions will be obtained from the mid-labial surface of the central incisor region of the thermoformed aligners, both immediately after thermoforming and after two weeks of intraoral wear. The full thickness of the material will be preserved in all specimens to ensure consistency across groups. Outcomes: Primary Outcome: Surface Roughness (Ra): Measured at three stages: T0: Raw, unused sheet specimens (baseline) T1: After thermoforming on dental casts T2: After 2 weeks of intraoral use Secondary Outcomes: Hardness: Measured at T0, T1, and T2. Tested using Vickers hardness method (ISO 6507 compliant).

Official title: Evaluation of Physical Changes in Single-Layer and Multi-Layer Clear Aligners After Thermoforming and Intraoral Wear

Key Details

Gender

All

Age Range

16 Years - 24 Years

Study Type

INTERVENTIONAL

Enrollment

20

Start Date

2026-01-01

Completion Date

2027-02-01

Last Updated

2026-03-04

Healthy Volunteers

No

Interventions

DEVICE

clear aligner

Appliance Fabrication and Treatment Protocol * Digital impressions will be taken for all patients. * Treatment setup will be performed with standardized staging: maximum 0.25-0.3 mm linear movement or 2-3° rotation per stage. * Aligners will be fabricated by thermoforming using single and multilayer sheets (0.76 mm), cut and finished identically.

Locations (1)

Mansoura university

Al Mansurah, Egypt