Tundra Space

Tundra Space

Clinical Research Directory

Browse clinical research sites, groups, and studies.

Back to Studies
NOT YET RECRUITING
NCT07457645
NA

Safety and Efficacy of High-Channel Implanted BCI for Motor Function Improvement in Tetraplegia Patients

Sponsor: Shanghai Zhongshan Hospital

View on ClinicalTrials.gov

Summary

This is an open-label single-arm clinical study conducted at designated clinical trial institutions, with three overall phases: a 3-month main study, a 3-month extension, and a 3-month follow-up. The main study includes screening/baseline, preoperative preparation, surgery, upper limb rehabilitation adjustment, and pneumatic hand function training-specifically, preoperative brain and spinal cord imaging for electrode placement in eligible subjects, implantation of high-channel electrodes, and postoperative combined rehabilitation to build a motor intention decoding model that drives the pneumatic hand to grasp. The extension phase focuses on precise assessment of upper limb grasping function, signal stability monitoring, implantation of epidural spinal cord test electrodes, and closed-loop regulated epidural electrical stimulation for limb rehabilitation using implanted intracranial electrode signals. The follow-up phase involves intracranial electrode removal, implantation of long-term epidural spinal cord electrodes, and limb rehabilitation training and observation based on scalp EEG signals.

Official title: Safety and Efficacy of High-Channel Implanted Brain-Computer Interface in Promoting Motor Function Improvement in Patients With Tetraplegia

Key Details

Gender

All

Age Range

18 Years - 65 Years

Study Type

INTERVENTIONAL

Enrollment

10

Start Date

2026-03-15

Completion Date

2028-10-15

Last Updated

2026-03-09

Healthy Volunteers

No

Interventions

OTHER

Invasive BCI

Main Study Phase: Subjects undergo intracranial electrode implantation surgery. After surgery, motor intention decoding is performed on the electroencephalographic (EEG) signals recorded by the intracranial electrodes, and the decoded signals drive an external hand continuous passive motion device to achieve upper limb grasping movements. Extension Phase: Subjects receive implantation of epidural spinal cord test electrodes, and undergo rehabilitation training with closed-loop epidural electrical stimulation based on signals from the implanted electrodes. Follow-up Phase: It mainly involves functional training with closed-loop epidural electrical stimulation based on scalp EEG signals, as well as follow-up observation.

Locations (1)

Shanghai Zhongshan Hospital

Shanghai, Shanghai Municipality, China