Tundra Space

Tundra Space

Clinical Research Directory

Browse clinical research sites, groups, and studies.

Back to Studies
RECRUITING
NCT07532811
NA

Evaluation of Perfusion and Ventilation Distribution in Children: a Pilot Study.

Sponsor: Hospices Civils de Lyon

View on ClinicalTrials.gov

Summary

Electrical impedance tomography (EIT) is a recent monitoring technique that provides information on regional ventilation distribution. Following the injection of a hypertonic saline bolus, EIT can also assess regional pulmonary perfusion distribution, allowing evaluation of the ventilation/perfusion (V/Q) ratio. In adults, protocols for assessing perfusion distribution require the injection of 10 mL of a 7.5% or 10% NaCl solution or sodium bicarbonate over a few seconds. Studies have reported good hemodynamic tolerance, adequate image quality, and no significant changes in serum sodium levels. However, this volume and sodium load are not appropriate for small children. To date, no pediatric protocol exists for assessing pulmonary perfusion distribution and the ventilation/perfusion ratio using EIT. It is therefore proposed to conduct a pilot study to evaluate the feasibility of assessing pulmonary perfusion by EIT using a weight-adjusted bolus of hypertonic saline (NaCl or sodium bicarbonate).

Official title: Feasibility Study of the Evaluation of Perfusion and Ventilation Distribution in Children : a Pilot Study

Key Details

Gender

All

Age Range

Any - 12 Years

Study Type

INTERVENTIONAL

Enrollment

20

Start Date

2026-05-13

Completion Date

2028-08-13

Last Updated

2026-05-19

Healthy Volunteers

No

Interventions

OTHER

Evaluation of perfusion with Electrical impedance tomography using sodium chloride or sodium bicarbonate

All patients will undergo EIT monitoring (Enlight 2100, Timpel, Brazil) using a belt adjusted to the thoracic circumference. Ventilation distribution will be assessed with a tidal volume of 8 mL/kg. Following a breath hold, a saline solution (sodium chloride or sodium bicarbonate) will be injected over a few seconds. Perfusion distribution, as well as impedance signal variation, will be recorded using dedicated software (Timpel, Brazil). Data acquisition will be considered valid if the impedance signal variation induced by the saline solution injection is at least equivalent to the amplitude variation observed during ventilation with a tidal volume of 8 mL/kg. 2 measurements at 4 to 6-hours intervals with volume or concentration adjustment after the first injection if needed in the group 1

Locations (1)

Florent BAUDIN

Bron, France, France